AXIS 207/207W/207MW Installation Guide
7. Adjust the focus
Focus ring
(inner ring)
Status indicator
(outer ring)
Note:
Upon delivery, the raised line on the focus ring is aligned with the dot
above the lens, and the focus is set to infinity.
Resetting to the Factory Default Settings
This will reset all parameters, including the IP address, to the Factory Default settings:
1. Disconnect power from the camera.
2. Press and hold the Control button and reconnect power.
3. Keep the Control button pressed until the Status indicator displays amber (this may take
up to 15 seconds), then release the button.
4. When the Status indicator displays green (which can take up to 1 minute) the process is
complete and the camera has been reset.
5. Re-install the AXIS 207/207W/207MW using one of the methods described in this
document.
It is also possible to reset parameters to the original factory default settings via the web
interface. For more information, please see the online help or the user's manual.
Small dot above the lens
assembly.
Raised line on
focus ring.
Page 15
To focus:
Open a browser and
examine the image. If
required, adjust the focus
ring until the focus is
satisfactory.