3.1
INSTALLATION MENU.
Press 5 seconds on the (OK) to enter in the installation
menu.
When you enter on the installation menu (the first pa-
rameter "Syst" is displayed), you could choose another
parameter by pressing the navigation key (OK).
Once the desired parameter displayed you can change
the value with the keys (
3.1.1 Lock function.
To prevent mistakes after installation, all critical parame-
ters (system and Extra function) are not accessible any
more after 4 hours power on. If you want to modify these
parameters, you must unplug and plug in controller. No
settings are lost when unplugging, or after a power failure.
After 4 hours you can still change all the other settings
to optimize your system.
N.B.: Not all submenus, selections, or options di-
scussed in this manual are available on all systems.
Depictions of menus and submenus shown here are
representative of their actual appearance on the con-
trol when the same series of settings as is described
is followed.
▶
◀
+) or (-
).
3.2
SYSTEM CHOICE.
"SySt" parameter (Default value "1").
3.2.1 System 1.
With this system you can add extra functions with 1 or 2
sensors T3 (NTC) or T4 (PT1000) (Thermostat, Cooling,
Antistagnation or Diffcontrol function).
T1
P1
The loading of the tank1 is authorized if the temperature
difference "dt" between the collector (T1) and the tank1
(T2) is sufficient.
3.2.2 System 2.
System with 2 tanks, 1 pump, 1 valve, 1 collectors array
and 3 sensors. With this system you can add an extra
function with 1 sensor T4 (PT1000) (Thermostat, Coo-
ling, Antistagnation).
T1
P1
P2
The loading of the tanks is authorized if the temperature
difference "dt" between the collector (T1) and the tanks
(T2, T3) is sufficient. The valve direction is done the tank
which mus be loaded.
27
T2
T3
T2