Virutex CE223X Mode D'emploi page 11

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Unscrew screws Y (Fig. 19) and remove protection X.
Replace the worn belt Z with a VIRUTEX original spare,
taking care to fit it correctly into the pulley cogs, never
forcing it.
11. MAINTENANCE OF THE
BRUSHES AND COLLECTOR
Disconnect from the mains before ca-
rrying out any maintenance operations.
The brushes must be replaced when they reach a minimum
length of 5 mm (Fig. 5)
Changing brushes.
Unscrew the black caps Q1 (Fig. 1) on the housing and
remove the brushes from the guide. Replace them with
new Virutex original spares, ensuring that they move
smoothly inside the guides. Screw on the cap which covers
them and leave the machine running for 15 minutes.
If the collector is burned or uneven it should
be repaired by a Virutex service agent.
12. CLEANING THE MACHINE
It is important to always clean the machine carefully
after use with a dry air blower.
Keep the power cable in perfect condition.
Keep the machine's vent and cooling openings clean
and unobstructed.
13. NOISE AND VIBRATION LEVEL
The noise and vibration levels of this device have been
measured in accordance with European standard EN
60745-2-14 and EN 60745-1 and serve as a basis for com-
parison with other machines with similar applications.
The indicated vibration level has been determined for
the device's main applications and may be used as an
initial value for evaluating the risk presented by expo-
sure to vibrations. However, vibrations may reach levels
that are quite different from the declared value under
other application conditions, with other tools or with
insufficient maintenance of the electrical device or its
accessories, reaching a much higher value as a result
of the work cycle or the manner in which the electrical
device is used.
Therefore, it is necessary to establish safety measures
to protect the user from the effects of vibrations, such
as maintaining both the device and its tools in perfect
condition and organising the duration of work cycles
(such as operating times when the machine is subjected
to loads, and operating times when working with no-load,
in effect, not in use, as reducing the latter may have a
considerable effect upon the overall exposure value).
14. WARRANTY
All VIRUTEX power tools are guaranteed for 12 months
from the date of purchase, excluding any damage which
is a result of incorrect use or of natural wear and tear
on the machine. All repairs should be carried out by the
official VIRUTEX technical assistance service.
15. RECYCLING ELECTRICAL EQUIPMENT
Never dispose of electrical equipment with domestic was-
te. Recycle equipment, accessories and packaging in ways
that minimise any adverse effect on the environment.
Comply with the current regulations in your country.
Applicable in the European Union and in European
countries with selective waste collection systems:
If this symbol appears on the product or in the accom-
panying information, at the end of the product's useful
life it must not be disposed of with other domestic waste.
In accordance with European Directive 2002/96/EC, users
may contact the establishment where they purchased the
product or the relevant local authority to find out where
and how they can take the product for environmentally
friendly and safe recycling.
VIRUTEX reserves the right to modify its products
without prior notice.
F R A N Ç A I S
RABOT DUO CE223X
(Voir images pages 48, 49, 50)
1. INSTRUCTIONS DE SÉCURITÉ
Avant d'utiliser la machine, veuillez lire at-
tentivement la BROCHURE D'INSTRUCTIONS
GÉNÉRALES DE SÉCURITÉ qui est jointe à
la documentation de la machine.
1. Vérifier avant de brancher la machine si la tension
d'alimentation correspond à celle indiquée sur la plaque
des caractéristiques.
2. Avant de mettre en marche la machine, s'assurer que
11