MasterCraft 62-3523-0 Guide D'utilisation page 2

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety
DESCRIPTION
This submersible sump pump is designed for home
sumps. Unit is equipped with a 3-prong grounding-type
power cord. Ball bearings on motor shaft never need
lubrication. Automatic reset thermal protection.
SPECIFICATIONS
Power supply required ................................115 V, 60 Hz
Motor duty ....................................................continuous*
Liquid Temp. Range .................32° to 77° F (0° to 25° C)
Individual Branch Circuit Required (minimum) ..10 Amps
Discharge Adapter: .......................................1 1/4" FNPT
*NOTICE: For continuous operation, water depth must be
at least 5" (13 cm), to prevent motor from overheating.
NOTICE: This unit is not designed for applications
involving salt water or brine! Use with salt water or
brine will void warranty.
PERFORMANCE
GPH (LPH) AT TOTAL FEET (M)
Motor
Series
HP
(1.5 m)
CAPACITY GALLONS(L)/HOUR
2100
62-2523-0
4/10
(7,949)
ELECTRICAL & SWITCH
SPECIFICATIONS
Motor
Motor Full Load Branch Circuit
Series
HP
Amps
62-3523-0
4/10
3.0
Mastercraft warrants that the products specified in this warranty are free from defects in material or
workmanship.
If within two (2) years from the date of the original consumer purchase, this pump shall prove to be defec-
tive, it shall be repaired or replaced subject to the terms and conditions set forth below.
General Terms and Conditions
This warranty shall not apply to acts of God, nor shall it apply to products which have been subject to neg-
ligence, abuse, accident, misapplication, tampering, alteration; nor due to improper installation, operation,
maintenance or storage; nor to other than normal application, use or service, including but not limited to,
operational failures caused by corrosion, rust or other foreign materials in the system, or operation at pres-
sures in excess of recommended maximums as set forth in the owner's manual.
Requests for service under this warranty shall be made by returning the product to the retail outlet as soon
as possible after the discovery of any defect. We will subsequently take corrective action as promptly as rea-
sonably possible.
This warranty sets forth our sole obligation and the purchaser's exclusive remedy for defective products.
5
10
15
No flow
at height
(3 m)
(4.5 m)
shown
below
1700
925
18 Ft.
(6,435)
(3,501)
(5.5 M)
Individual
*Switch Setting
in inches (mm)
Req. (Amps)
On
Off
10
11" (279) 5" (127)
Limited Warranty
For parts or assistance, call customer service at
GENERAL SAFETY INFORMATION
Electrically powered sump pumps normally give many
years of trouble-free service when correctly installed,
maintained, and used. However, unusual circumstances
(interruption of power to the pump, dirt/debris in the
sump, flooding that exceeds the pump's capacity, electri-
cal or mechanical failure in the pump, etc.) may prevent
your pump from functioning normally. To prevent possible
water damage due to flooding, consult your retailer about
a secondary AC sump pump, a DC backup sump pump,
and/or a high water alarm. See the "Troubleshooting
Chart" in this manual for information about common
sump pump problems and remedies. For more informa-
tion, call customer service at 1-877-455-5508.
1. Know the pump application, limitations, and poten-
tial hazards.
2. Disconnect power before servicing.
3. Release all pressure within system before servicing
any component.
4. Drain all water from system before servicing.
5. Secure discharge line before starting pump. An unse-
cured discharge line will whip, possibly causing per-
sonal injury and/or property damage.
6. Check hoses for weak or worn condition before each
use, making certain that all connections are secure.
7. Periodically inspect sump, pump and system compo-
nents. Keep them free of debris and foreign objects.
Perform routine maintenance as required.
8. Provide means of pressure relief for pumps whose
discharge line can be shut off or obstructed.
1-877-455-5508
2

Publicité

Table des Matières
loading

Table des Matières