Changing gas group within the same family
Check that the appliance is suitable for operation with the gas group in question.
Check in the appliance instruction booklet if any operations are necessary when changing the gas group.
If so, adjust the minimum and maximum gas outlet pressures in accordance with the instructions for the appliance
and the instructions in this catalogue.
IMPORTANT: At the end of all setting and adjustment operations, check electrical insulation, gas seals and the
efficiency of the appliance. In particular, it is necessary to ensure that the flame does not go out and that back-firing
does not occur at the minimum and maximum gas outlet pressures.
After carrying out all adjustments, fit the provided seals and/or block the setting screws with paint, taking care not to
obstruct the orifice of the pressure regulator.
ACCESSORIES
Connector for EV1 and EV2 type 150 L = 500 mm
Seal and screw for connector type 150
Connector type 360 for step type modulating valve including
rectifying circuit, seal and screw
Elbow flange with screws and O-ring
Straight flange with screws and O-ring
Other accessories are available on request
0.960.114
0.960.108
0.960.118
0.906.265
0.906.266
7