Instruction Manual BDC3140 DBP/LPP-3020
Tightness inspection
1.
Suction connecting hose
2.
Hose
Hoses check
■
Make sure that the suction connecting hose (1) is in a
good condition and correctly fixed.
If the hose is damaged, broken or badly connected to
the unions, it must be replaced.
When sticky materials are treated, check for possible
clogging along the hose (2), in the inlet and on the
baffle plate inside the filtering chamber.
Scrape the inlet from the outside and remove the
deposited waste as indicated in the figure.
1.
Seal
2.
Screws
3.
Filtering chamber
■
Filtering chamber tightness check
If the gasket (1) between the container and the filtering
chamber (3) fails to guarantee tightness:
▪
Loosen the four screws (2) that lock the filtering
chamber (3) against the vacuum cleaner structure.
▪
Allow the filtering chamber (3) to lower down and
tighten the screws (2) once it has reached the
tightness position.
The gasket (1) must be replaced if it is torn, cut, etc.
Disposing of the vacuum cleaner
Dispose of the vacuum cleaner in compliance with the laws
in force.
Proper disposal (electric and electronic waste).
■
(Applicable in the European Union and in
countries providing a separate collection system)
GB
The above symbol (Fig. 14), which is present on the product
or in its documentation, indicates that the product cannot be
disposed of together with other domestic waste at the end of
its life cycle.
To prevent damage to the environment or health caused by
improper waste disposal, please separate this product from
other waste and recycle it responsibly in order to support the
sustainable reutilisation of material resources.
This product cannot be disposed of together with other
commercial waste.
Figure 12
Figure 13
Figure 14
Wiring diagrams
Figure 15 - 16
Item
Part
Q1
Main switch
Circuit breaker
Q2
9-12,5 A
Circuit breaker
Q3
1,1-1,6 A
KM1
Contactor
TS2
Cyclic timer
www.blastrac.eu ‒ info@blastrac.eu
10/16
400V
50Hz
8 39556
4083901540
4083901545
4083901533
4083901545
4083901550
8 391107