4.1.3 APPLIANCE VENT CONNECTION

NOTE : Fastening hardware provided with appropriate kit.
A.
Attach the adjustable pipe to the last section of rigid pipe.
Secure with screws and seal.
B.
Install the inner fl ex pipe to the appliance. Secure with 3
screws. Seal the joint and screw holes using Mill Pac sealant
(W573-0007) (not supplied).
C.
Run a bead of Red RTV Silicone (W573-0002) (not supplied)
around the inside of the air intake collar. Pull the adjustable
pipe a minimum 2" (50.8mm) into the air intake collar.
NOTE: Ensure that the sealant is not visible on the exterior pipes once installation is completed. An optional
decorative black band is available for this use. In the event that the venting must be disassembled, care
must be taken to reseal the venting.
2" (50.8mm)
SCREWS
OVERLAP
HIGH TEMPERATURE
SEALANT
28.3C
W415-2183 / B / 02.10.17