Minimum Air Terminal Location Clearances - Napoleon GDS26N-1 Instructions D'installation Et D'opération

Masquer les pouces Voir aussi pour GDS26N-1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.4

MINIMUM AIR TERMINAL LOCATION CLEARANCES

INSTALLATIONS
CANADA
A
12" (30.5cm)
12" (30.5cm)
12"
B
9" (228.6mm)
(30.5cm)
Δ
C
12" (30.5cm)*
12" (30.5cm)*
D
18" (45.7cm)**
18" (45.7cm)**
E
18" (45.7cm)**
18" (45.7cm)**
F
0" (0mm)
0" (0mm)***
G
2" (50.8mm)***
2" (50.8mm)***
H
3' (0.9m)
3' (0.9m)****
I
3' (0.9m)
3' (0.9m) ****
J
12" (30.5cm)
9" (228.6mm)
K
6' (1.8m)
L
7' (2.1m) ‡
7' (2.1m) ****
12"
M
(30.5cm)††
(30.5cm)****
N
16" (40.6cm)
16" (40.6cm)
O
2' (0.6m)†*
P
8' (2.4m)
Q
3' (0.9m)
R
6' (1.8m)
Δ
In a structure with three walls and a roof, the terminal shall not be located less than 6 feet (1.8m) under a window that opens on a horizontal plane.
*
Recommended to prevent condensation on windows and thermal breakage
**
It is recommended to use a heat shield and to maximize the distance to vinyl clad soffits.
***
The periscope requires a minimum 18" (45.cm) clearance from an inside corner.
****
This is a recommended distance. For additional requirements check local codes.
3 feet above if within 10 feet (3.1m) horizontally.
A vent shall not terminate where it may cause hazardous frost or ice accumulations on adjacent property surfaces.
††
Permitted only if the veranda, porch, or deck is fully open on a minimum of two sides beneath the floor.
†*
Recommended to prevent recirculation of exhaust products. For additional requirements check local codes.
NOTE: Clearances are in accordance with local installation codes and the requirements of the gas supplier.
U.S.A.
Clearance above grade, veranda porch, deck or balcony.
Clearance to windows or doors that open.
Δ
Clearance to permanently closed windows.
Vertical clearance to ventilated soffits located above the terminal within a horizontal distance of
2' (50.8mm) from the centerline of the terminal.
Clearance to unventilated soffit.
0" (0mm)
Clearance to an outside corner wall.
Clearance to an inside non-combustible corner wall or protruding non-combustible obstructions (chim-
0" (0mm)***
ney, etc.).
Clearance to an inside combustible corner wall or protruding combustible obstructions (vent
chase, etc.).
Clearance to each side of the centerline extended above the meter / regulator assembly to a
maximum vertical distance of 15' (4.6m).
Clearance to a service regulator vent outlet.
Clearance to a non-mechanical air supply inlet to the building or a combustion air inlet to any other
appliance.
3' (0.9m) †
Clearance to a mechanical air supply inlet.
Clearance above a paved sidewalk or paved driveway located on public property.
12"
Clearance under a veranda, porch, deck or balcony.
Clearance above the roof.
2' (0.6m)†*
Clearance from an adjacent wall including neighbouring buildings.
Roof must be non-combustible without openings.
8' (2.4m)
3' (0.9m)
See chart for wider wall dimensions.
See chart for deeper wall dimensions. The terminal shall not be installed on any wall that has an
6' (1.8m)
opening between the terminal and the open side of the structure.
COVERED BALCONY APPLICATIONS
Q
R
Q
= 3 feet
R
= 2 x
MIN
Q
MAX
ACTUAL
(0.9m)
13
EN
M
P
G
R
≤ 15 feet
MAX
(4.6m)
W415-2183 / B / 02.10.17