Specifications
1000 measurement results with respective
Memory
date and time
Dimensions
110 (L) x 57 (W) x 25 (H) mm
Power Source
3V
Weight
71g
Serial Cable (for TD-4272G / GD40g)
External output
Bluetooth (for TD-4272H / GD40h)
Auto electrode insertion detection
Auto sample loading detection
Auto reaction time count-down
Features
Auto switch-off after 3 minutes without
action
Temperature warning
10°C to 40°C (50°F to 104°F), below 85%
Operating Condition
R.H. (non-condensing)
Storage/Transportation
-20°C to 60°C (-4°F to 140°F), below 95%
Condition
R.H
either mg/dL or mmol/L for glucose test
Measurement Units
and fixed mmo/L for β-Ketone test
10 to 600 mg/dL (0.5 to 33.3 mmol/L)
Measurement Range
for glucose test and 0.1~8.0 mmol/L for
β-Ketone test
0~70% for glucose testing and 10~70% for
Hematocrit range
β-Ketone test
Test Sample
Capillary whole blood
Glucose measurements are reported as
Test Result
plasma equivalents
(Two 1.5V AAA alkaline batteries)
This device has been tested to meet the electrical and safety
requirements of: IEC/EN 61010-1, IEC/EN 61010-2-101, EN 61326-1, IEC/
EN 61326-2-6, EN 301 489-17, EN 300 328.
WARRANTY TERMS AND CONDITIONS
With respect to disposable products, ForaCare Suisse warrants
to the original purchaser that, at time of delivery, each standard
product manufactured by ForaCare Suisse shall be free of defects
in material and workmanship and, when used for the purposes
and indications described on the labeling, is fit for the purposes
and indications described on the labeling. All warranties for a
product shall expire as of the product expiration date, or if none,
after two (2) year from the original date of purchase, as long as
it has not been modified, altered, or misused. ForaCare Suisse
warranty hereunder shall not apply if:
(i) a product is not used in accordance with its instructions or if it
is used for a purpose not indicated on the labeling; (ii) any repairs,
alterations or other work has been performed by the buyer or
others on such item, other than work performed with ForaCare
Suisse's authorisation and according to its approved procedures;
or (iii) the alleged defect is a result of abuse, misuse, improper
maintenance, accident or the negligence of any party other than
ForaCare Suisse. The warranty set forth herein is conditioned upon
proper storage, installation, use and maintenance in accordance
with applicable written recommendations of ForaCare Suisse.
The warranty furnished hereunder does not extend to damaged
items purchased hereunder resulting in whole or in part from the
use of components, accessories, parts or supplies not furnished by
ForaCare Suisse.
EN-16