Problem
The compressor does not run. □
The motor hums while
running slowly, or it doesn't
run at all.
Possible Cause
There is a loss of power or
the motor is overheated.
There is no power to the unit.
The circuit breaker has
tripped or a fuse has blown
at the main power source.
The thermal overload
protector is actuated.
The pressure switch is bad.
The compressor has reached
automatic shutoff pressure.
There is low voltage from the
power source.
The wrong gauge wire or
length of extension cord is
being used.
There is a shorted or open
motor wiring.
There is a defective check
valve or unloader.
Solution
Check for proper use of extension
cord.
Check to be sure the unit is plugged
in.
Check the fuse/breaker.
Turn the air compressor OFF ( O ).
Unplug air compressor and wait until
compressor cools down.
Plug the air compressor into an
approved outlet.
Turn the air compressor ON ( I ).
Bring the compressor to a service
center.
Release the air from the tank until the
compressor restarts automatically.
Call an electrician.
Check for proper gauge wire and cord
length.
Bring the compressor to a service
center.
Bring the compressor to a service
center.