4. Technical data

Mains voltage: ................................230V ~ 50 Hz
Rated input current ..................................... 2.3 A
Power rating: ............................................. 430 W
Rated out-
6 V d.c.
put voltage
Rated
0,7 A arith.
output
0,9 A eff .
current min
Rated
21 A arith.
output
30 A eff .
current max.
Battery
5-400 Ah
capacity
Jump star-
80 A arith.
ting current
100 A eff .
max.
Minimum battery capacity setting 1-6
1
2
6 V
5 Ah
7 Ah
10 Ah
12 V
3 Ah
5 Ah
7 Ah
24 V
4 Ah
5 Ah
7 Ah

5. Before starting the equipment

The jump starting function provides welcome
help with starting diffi culties due to too little
battery capacity.
Consult the manuals published by the vehicle
manufacturer and the battery manufacturer
for information about charging the battery
and about jump starting. Charge the battery
only at the connection points specifi ed by the
vehicle manufacturer. This also applies to the
use of any jump start functions which might
be provided on the charger. Failure to obser-
ve the information published by the vehicle
manufacturer and the battery manufacturer
might result in damage to the vehicle or to
the battery.
Charging for 10 minutes at the highest char-
ge setting is usually suffi cient for starting a
vehicle without jump starting.
Anl_CC_BC_30-1_SPK9.indb 14
Anl_CC_BC_30-1_SPK9.indb 14
12 V d.c
24 V d.c.
1,0 A arith.
1,8 A arith.
1,6 A eff .
3,0 A eff .
20 A arith.
14 A arith.
30 A eff .
20 A eff .
3-400 Ah
4-400 Ah
80 A arith.
80 A arith.
100 A eff .
100 A eff .
3
4
5
6
25 Ah
70 Ah
150
Ah
18 Ah
45 Ah
80 Ah
15 Ah
33 Ah
50 Ah
- 14 -
GB

5.1 Charging the battery:

Release or remove the battery stoppers (if
fitted) from the battery.
Check the acid level in the battery. If neces-
sary, top up the battery with distilled water (if
possible). Important. Battery acid is aggres-
sive. Rinse off any acid splashes thoroughly
with lots of water and seek medical advice if
necessary.
Select the charging voltage. Pay particular
attention to the voltage details on the battery
you wish to charge. Select the charging cur-
rent (amps) according to numbers 1 (lowest
charging current) to 6 (highest charging
current). Note the minimum capacity of the
battery in section 4. Technical data.
First connect the red charging cable to the
positive pole of the battery.
Then connect the black charging cable to the
bodywork of the vehicle away from the battery
and the petrol pipe.
Warning! Under normal circumstances the
negative battery pole is connected to the
bodywork and you proceed. In exceptional
cases it is possible that the positive battery
pole is connected to the bodywork (positive
earthing). In this case connect the black
charging cable to the negative pole on the
battery. Then connect the red charging cable
at a point away from the battery and the petrol
pipe.
After the battery has been connected to the
charger, you can connect the charger to a
socket supplying 230V~50Hz. Do not connect
it to a socket that supplies any other mains
voltage. Important. Charging may create
dangerous explosive gas and therefore you
should avoid spark formation and naked fla-
mes whilst the battery is charging. There is a
risk of explosion!
Calculating the charging time
The charging time depends on the charge status
of the battery. If the battery is fully discharged,
the approximate charging time can be calculated
using the following formula:
Battery capacity in Ah
Charging time/h =
Amp. (arithmetic charging
current)
24 Ah
Example =
= 9,6 h max.
2,5 A