Maintenance And Care - Tornado DE 4002 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Storing the Appliance
 Place the manual nozzle, detail nozzles
and small parts into the accessories
storage box.
 Wrap the cable around the holder on
the floor of the appliance. Insert the ex-
tension pipes individually into the re-
cesses on the appliance floor.
Note
Always allow the brushes to cool down for
a sufficient period of time to avoid a defor-
mation of the bristles.

Maintenance and care

Danger
Always disconnect the mains plug and al-
low the steam cleaner to cool down before
performing any maintenance work.
Rinsing the boiler
Rinse the boiler of the steam cleaner boiler
at the latest after 5 boiler fillings.
 Fill the boiler with water and shake it
strongly. This dissolves lime scaling re-
siding on the boiler bottom.
 Empty water out.
Descaling the boiler
Note
If you always use usual commercial distilled
water it is not necessary to descale the boil-
er.
Warning
Only use products approved by Tornado to
exclude any damages of the appliance.
 Disconnect the mains plug from the
socket.
 Completely empty the steam boiler.
 Completely dissolve two bags of des-
caler by stirring it in 0.5 gal (2 liters) of
warm water.
 Fill the descaling solution into the boiler
and allow to react for approximately 8
hours.
Danger
Do not screw the steam boiler safety cap on
the appliance during the descaling. Do not
use the appliance as long as there is des-
caling agent in the boiler.
 Pour out the descaling solution. Rinse
the boiler at least two more times with
cold water to ensure that there is no res-
idue left behind in the boiler.
 Turn on the appliance.
 Press the reset key until the indicator
lamp "Descaling" goes off.
The appliance is ready for use again. After
approx. 50 operating hours, the indicator
lamp "Descaling" shows the next neces-
sary descaling process.
Filter replacement
Using soiled water can occlude the filter.
This is shown by extraordinaly long run
times of the pump or a complete malfunc-
tion.
 Replac the filter.
– 8
EN
13

Publicité

Table des Matières
loading

Table des Matières