5.5 Cable entry
To maintain the IP degree of protection
of the product, use cable glands with
adequate IP.
To maintain UL certification, the cable
glands used must be UL certified.
All the cable glands must be suitable for the
use conditions and installed correctly.
The product is supplied without drilling. It is
suggested to perforate the box on the short side
indicated in the figure (Fig. 6, page 11).
Fig. 6
Before perforating the box, remove the internal block
(01) composed of a support plate, connectors board,
switch board, transformer and splice tray.
To remove the internal block (01), unscrew the four
fastening screws (02).
Hold the board division plate (03), lift the internal
block (01) and remove the box (04) (Fig. 7, page 11
and Fig. 8, page 11).