Key:
Layout confirmation
Print after measuring
Key:
Standard layout

I/O Parameters

Keys:
,
,
,
IN signal level
Key:
OUT signal level
Key:
Debouncing
Key:
Start signal delay
Key:
Not ready: error
Key:
I/O Profile

Network

Keys:
,
,
,
For more information, please see the separate manual.
132
On: A new print order is only printed after confirmation at the device.
An already active continuing print order is printed as long as the confirmation is effected at the
device.
Off: No query appears at the display of control unit.
On: If an error occurred during printing, whose removal can be recognized by the module (e.g.
transfer ribbon end, cassette open), then the module changes after the error correction (e.g.
cassette closed again) immediately in the 'ready' mode.
Off: After removal and confirmation of error, the module changes into 'stopped' mode.
On: If a print order is started without previous definition of layout, the standard layout (device
type, firmware version, build version) is printed.
Off: If a print order is started without previous definition of layout, an error message appears in
the display.
,
,
,
Indication of signal at which a print order is started.
+ = active signal level is 'high) (1)
− = active signal level is 'low' (0)
x = not activated signal level
s = status can be affected by interface (in combination with Netstar PLUS)
Indication of signal level for output signal.
+ = active signal level is 'high) (1)
− = active signal level is 'low' (0)
s = status can be affected by interface (in combination with Netstar PLUS)
Indication of debounce time of the dispenser input.
Value range: 0 ... 100 ms.
Indication in time per second of the delay for the start signal.
Value range: 0.00 ... 9.99.
On: If a print order is active but the direct print module is not ready to process the order (e.g. if it
is already in 'printing' mode), then an error message appears.
Off: No error message appears.
Selection of the existing configuration Std_Direct or StdFileSelDirect. The appropriate
assignment is indicated in the operating manual.
,
,
,
,