Warning:
Install the relay unit in a dry and protected place without risk of drip or water projections.
To avoid damage, the relay unit has to be firmly fixed.
The minimum wire section to connect in the relay outputs will be of 1,5mm .
To avoid an electrical shock, neither remove the protection cover nor handle the connected
wire in the terminals with the symbol
be performed by authorized personnel and in the absence of electrical current.
In case of blown fuse, replace for one of the same characteristics (see page 33).
The blown fuse must be replaced by authorized personnel and in the absence of electrical
current.
The maximum current for relay contacts will be of 1.8A at 30 Vdc/250 Vac.
For safety the cover of the fuseholder must always be placed.
Important:
To avoid an electrical shock, the installation and handling of the relay unit must be performed
by authorized personnel and in the absence of electrical current.
SAFETY PRECAUTIONS
, the installation and handling of the relay unit must
To access the output terminals of the relay, remove the
protection cover using flat pliers, by a light pressure
on the ribs wall and then pull to remove it.
Remember:
When the installation and wiring works are finished,
make sure the protection cover and fuseholder are
placed in the relay unit before replacing the electrical
current.