Oase VarioSwitch 010a/24 V Notice D'emploi page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- GB -
Accessing the solenoid valves
Nozzle
Brown single wire (BN)
0 V
DC 24 V
0 V
DC 24 V
Pos: 28 /Pumpen/Schlammsauger/VarioSwitch 10, 15/Reinigung Vario Switch 10-15 @ 5\mod_1168342139725_121.doc @ 31935 @
Cleaning (C)
The unit need only be cleaned when required. Use a brush and clear water to clean the outside. Clean the water and
air channels with a soft bottle brush. For this purpose, remove the plug (8) and the snorkel (7).
Pos: 29 /Pumpen/Schlammsauger/VarioSwitch 10, 15/Lagern/Überwintern Vario Switch 10-15 @ 5\mod_1168335723631_121.doc @ 31909 @
Storage/Over-wintering
The unit is not frost proof. Take the unit out of the water and fully drain the residual water from the unit. Thoroughly
clean the unit and check for damage. Cover the unit with a frost protection cover.
Pos: 30 /Alle Produkte/Entsorgung/Entsorgung - gem. Bestimmungen @ 8\mod_1223247321369_121.doc @ 53910 @
Dispose of the unit in accordance with the national legal regulations.
Pos: 31 /Pumpen/Schlammsauger/VarioSwitch 10, 15/Störung VarioSwitch 10, 15 @ 5\mod_1164799994168_121.doc @ 29841 @
Malfunction
Malfunction
No water at nozzle outlet or bypass
Water escapes from both outlets
Toggling between the two outlets (nozzle /
bypass) is not possible
The unit automatically switches back to
the previous position
Pos: 32 /Pumpen/Schlammsauger/VarioSwitch 10, 15/Reparatur Vario Switch 10-15 @ 5\mod_1168354227975_121.doc @ 32013 @
Repair (G-O)
Switch the Vario Switch voltage free!
Opening the Vario Switch (G-I): Unscrew the Vario Switch from the connection tube (11). Undo and remove the screws
(14 and 17). Start with removing the connection unit (16), continue with the removal of the metal sheet cheeks (15).
Remove the housing sealing rings (18) from both sides.
Replacing the solenoid valve (J-L): Remove the cable shoes of the power cable of the solenoid valve (21). Remove the
two screws (20) and take out the solenoid valve (21). Insert new O rings (22, 23) and a new bag of silicate (19). Install
a new solenoid valve (21) and fasten with two screws (20). Plug in the cable shoes of the control cable: Black (BK) and
blue (BU) at the solenoid valve for the bypass (21), brown (BN) and blue (BU) at the solenoid valve for the nozzle (24).
Assembling the Vario Switch (M-O): Fit new housing sealing rings (18) on both sides. Fit the metal sheet cheeks (15),
insert screws (14) including washer and circlip, then tighten. Place the O ring (25) on the connection unit (16), plug the
connection unit (16) into the housing (3) and tighten the screws (17).
Wrap Teflon tape (9) around the thread (10) of the connection unit (16), then screw the Vario Switch on
the connection tube (11).
Pos: 33 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1630 @
8
Bypass
Black single wire (BK)
DC 24 V
0 V
0 V
DC 24 V
Cause
Pump not switched on
Pump defective
Water line blocked
System pressure too low
Both solenoid valves are not accessed
Both solenoid valves are accessed
Incorrect pressure ratio between fountain outlet
and bypass
Channels in the unit soiled
No air supply from snorkel/breather
Solenoid valve soiled
Solenoid valve defective
Both solenoid valves are not accessed
Both solenoid valves are accessed
Incorrect pressure ratio between fountain outlet
and bypass
Solenoid valve soiled
Solenoid valve defective
Screws fastening the solenoid valve have loos-
ened
Seals in the unit defective
The solenoid valve is only accessed by one
voltage pulse.
Status
Fountain off, bypass on
Fountain on, bypass off
Malfunction, water escapes from both outlets
Remedy
Start pump
Check pump
Check, clean water line
Increase system pressure
Check control voltage
Only access one valve
Nozzle too small, select larger nozzle
Clean water channels
Clean air channels
Clean solenoid valve
Replace solenoid valve
Check control voltage
Only access one valve
Nozzle too small, select larger nozzle
Clean solenoid valve
Replace solenoid valve
Open the unit and tighten screws
Replace sealing rings
The solenoid valves for nozzle and bypass require
a constant voltage level

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Varioswitch 015a/24 v

Table des Matières