Names and Functions
1.
Operation mode
●
Used to display the current operation
mode: Cool, Heat, Vent, Fan, Dry or Auto.
●
In Auto mode, the actual operation mode
(Cool or Heat) will be also displayed.
●
Operation mode cannot be changed when
OFF is displayed.
Operation mode can be changed after
starting operation.
2.
Fan Speed
●
Used to display the fan speed that is set for
the indoor unit.
●
The fan speed will not be displayed if the
connected model does not have fan speed
control functionality.
3.
Setpoint display
●
Used to display the setpoint for the indoor
unit.
●
Use the Celsius/Fahrenheit item in the
main menu to select the temperature unit
(Celsius or Fahrenheit).
4.
Stand by for Defrost/Hot start
STANDBY
"
"
(See page 12.)
If ventilation icon is displayed in this fi eld:
●
Indicates that an energy recovery ventilator
is connected.
For details, refer to the Operation Manual
of the ERV.
5.
Message
The following messages may be
displayed.
"This function is not available"
●
Displayed for a few seconds when an
Operation button is pressed and the indoor
unit does not provide the corresponding
function.
●
In a remote control group, the message will
not appear if at least one of the indoor units
provides the corresponding function.
8
"Error: Push Menu button"
"Warning: Push Menu button"
●
Displayed if an error or warning is detected
(see page 47).
"Time to clean fi lter"
"Time to clean element"
"Time to clean fi lter & element"
●
Displayed as a reminder when it is time to
clean the fi lter or element (see page 45).
6.
Ventilation
●
Displayed when a energy recovery
ventilator is connected.
●
Ventilation Mode icon."
These icons indicate the current ventilation
mode (ERV only) (AUTO, ERV, BYPASS).
●
Air Purify ICON "
This icon indicates that the air purifying unit
(option) in operation.
7.
display
(See page 18.)
●
Displayed when the key lock is set.
8.
display
(See page 28.)
●
Displayed if the Schedule or Off timer is
enabled.
9.
Under Centralized control "
●
Displayed if the system is under the
management of a multi-zone controller
(option) and the operation of the system
through the remote controller is limited.
10.
Changeover controlled by the
master indoor unit "
(VRV only)
●
Displayed when another indoor unit on the
system has the authority to change the
operation mode between cool and heat.
ERV BYPASS "
AUTO
ERV
AIR
"
PURIFY
CENTRAL
CONTROL
"
MASTER
CONTROLLED
English
"