Configuration according to the incoming electricity supply
To configure the equipment according to the incoming electricity supply, use the
dial on the rear of the front panel or via the mobile/web app.
This adjustment is essential for the correct operation of the load modulator.
For app or web programming to take effect, the rotating selector must be in the
"NO LIMIT." position.
If the TMC100 transformer is not installed, the position of the dial must be in the
"NO LIMIT" position in order not to limit the load current.
Single-phase
Current
power
NO LIMIT. NO LIMIT.
10 A
2,3 kW
13 A
3 kW
15 A
3,45 kW
18 A
4,14 kW
20 A
4,6 kW
23 A
5,3 kW
25 A
5,75 kW
Three-phase
power
NO LIMIT.
6,928 kW
9 kW
10,392 kW
12,42 kW
13,856 kW
15,9 kW
17,321 kW
57
Single-phase
Current
power
28 A
6,44 kW
30 A
6,9 kW
35 A
8,05 kW
40 A
9,2 kW
45 A
10,35 kW
50 A
11,5 kW
55 A
12,65 kW
63 A
14,49 kW
Three-phase
power
19,32 kW
20,785 kW
24,249 kW
27,713 kW
31,177 kW
34,641 kW
37,95 kW
43,648 kW