for Living 052-9332-2 Guide De L'utilisateur page 13

Ventilateur de plafond affleurant, 42 po
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING! To avoid possible electric shock, switch off the power supply at the main fuse or
circuit breaker box before servicing.
Problem
Blade screws are loose.
The mounting bracket or canopy is
loose.
Screws securing decorative housing to
mounting bracket are loose.
Glass shade is loose.
Fan is noisy
Screws securing down rod to mounting
during
bracket are loose.
operation.
Wiring connectors are vibrating against
the inside of the canopy.
Light kit or light bulb is not firmly
attached.
Canopy is rattling against ceiling.
Motor housing screws are loose.
Fuse or circuit breaker is blown.
Loose or incorrect power line
Fan does
connections to the fan or switch wires.
not start.
Reverse switch is stuck in the middle.
Wires are not properly connected.
Light bulb is faulty.
Light does
not work.
Fan is in reverse mode (blades are
moving in a clockwise direction).
Fan does
not seem to
provide the
expected
Fan is not properly connected.
effects.
Screws securing blades to motor are
loose.
Fan
Screws securing blade assembly are
wobbles
loose.
or shakes
Mounting bracket is not tightened
excessively.
securely.
Possible Reason
Used electrical appliances are recyclable and should not be discarded in your regular domestic
waste. Please actively support us in conserving resources and protecting the environment by
returning this appliance to a collection centre (if available).
Solution
Tighten the blade screws.
Check and fasten the screws.
Check and fasten the screws.
Tighten by hand, as necessary.
Check and fasten the screws.
Disconnect power at fuse box, loosen
canopy and reposition connectors.
Remove and reattach.
Be sure canopy is not touching ceiling.
Check and fasten the screws.
Check main fuse and branch circuit fuses or
circuit breaker. Repair as necessary.
Check all the wiring connections to fan and
housing wiring. Repair as necessary.
Make sure the reverse switch is set to up or
down only.
Ensure wire connector in the switch housing
is connected.
Remove light bulb and replace with a new
one of the same type.
Counter-clockwise (forward) direction is
recommended in warm weather. Switch off
fan and power, and wait for rotation to stop.
Use the eraser end of a pencil to push the
forward/reverse switch up.
Adjust the fan so that the ends of the blades
have at least 12" (30 cm) clearance from
walls or other obstructions, in the centre of
the room.
Tighten the screws.
Tighten the screws.
Tighten the mounting bracket to the outlet box.
13

Publicité

Table des Matières
loading

Table des Matières