3
Check that O-ring is correctly positioned in new
full-burn nozzle for inner circular burner. Push
nozzle onto burner pipe. Screw new main nozzle
for outer circular burner all the way into nozzle
fitting.
4
Put on nozzle fitting and burner pipes. Put on
securing clips.
5
Set air-regulating tube to correct dimension after
loosening the screw (see nozzle table). Tighten
screw again.
6
Put stovetop in place and screw it tight. Put
burner parts and pan support in place,
positioning them correctly.
If it should be necessary to correct the low-setting
nozzle as the result of deviating gas types and
pressure, the flow rate can be increased by turning to
the left.
These burners do not require the primary air to be
adjusted.
Checking functions after the conversion:
The flames are adjusted correctly if no yellow tips are
visible. They must not go out when switching over
swiftly from the high to the low setting.
Note:
Stick the adhesive label included with the
nozzle set over the rating plate of the appliance to
document the changeover to a different gas type.
&
'
Service
Contact our Service department if your appliance
needs repair. Our central Customer Service Center
(see below) will also be happy to supply you with
details on a center close to you.
When you contact our Customer Service, please have
the E number and the FD number for your appliance
available. You can find the product data plate with
these numbers on the underside of the appliance.
Questions? Please contact us. We look forward to
hearing from you!
877-4-GAGGENAU
www.gaggenau-usa.com
5551 McFadden Avenue
Huntington Beach, CA 92649
9