Functioning Test - Nice Mindy A824 Instructions Et Recommandations Pour L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
6.7) PROGRAMMING PAUSE TIME:
When the automatic closing function is selected with the specific dip switch, a timer is activated that controls "Pause Time" after
an opening manoeuvre. At the end of this time a closing manoeuvre is automatically activated. If this time has never been
programmed it is set at 30 seconds but any time can be selected from 1 to 1023 seconds (about 17 minutes) following a certain
procedure.
To set "Pause Time" proceed as follows:
1 2 3 4 5 6 7 8 9 10
1) Set the 2-way dip switches as indicated; in this way "Pause Time Programming" is selected.
2) Select the time wanted with the 10-way dip switch:
Dip 1 On
Dip 2 On
Dip 3 On
Dip 4 On
Dip 5 On
Dip 6 On
Dip 7 On
Dip 8 On
Dip 9 On
Dip 10 On
So if you want a pause time of, let's say, 25 seconds, turn dip switches 5, 4 and 1 ON (the sum of 16+8+1=25).
3) Once you have selected the time you can proceed with the "Memorising procedure" Chap. 6.1.
"Pause Time" for automatic manoeuvres is memorised with this procedure.
6.8) CANCELLING THE MEMORY:
All the programmable parameters are stored on a permanent memory on the card; it could happen that you need to cancel all
1 2 3 4 5 6 7 8 9 10
what is stored in one go and to do this you have to proceed as follows:
1) Set the dip switches as indicated; in this way "Cancelling the Memory" is selected".
2) Now proceed to memorisation which, in this case, confirms cancellation.
With this operation all the parameters contained in the memory are cancelled. ATTENTION! with the memory reset it is as if the
gearmotor has never been installed so it will be impossible to move the gate normally; in this case, the first command to reach the
inputs or if the "OPEN" or "CLOSE" keys are pressed, an "Initial search for distances" procedure will be activated immediately.

7) FUNCTIONING TEST:

Once the connections have been checked and the travel limits programmed, actuator movement can be tested.
We recommend working in the "hold to run control" functioning mode with all functions deactivated (all switches off). In all cases
if the control key is released in the "hold to run control" mode the motor will stop immediately. If the Step-by-Step input is used
as the first movement command (after having switched on) it should be an opening manoeuvre. At this stage it is particularly
easy to use the small keys "AP" (Open) and "CH" (Close) on the card. By means of the command inputs, move the gates up to
the desired opening point "A", before which the "braking" phase should intervene so the gate reaches the set point at a speed
reduced by about 30%. Now carry out a closing movement until the closing point is reached. In this case too the gate should
start slowing before coming to a stop. Now test triggering of the safety devices: PHOTOCELL and PHOTOCELL1 in opening
have no effect while in closing they will stop movement.
The devices connected to the STOP input act both in the opening and closing manoeuvres, stopping movement.
If the automatic functioning mode is selected, at the end of the opening manoeuvre there is a "pause time" followed
automatically by a closing manoeuvre. Pause time, if not programmed, will be 30 seconds
Only now, when all the adjustments have been made and with the electricity off, do we advise you to connect the radio receiver.
32
11 12
= 1 Second
= 2 Seconds
= 4
"
= 8
"
= 16
"
= 32
"
= 64
"
= 128
"
= 256
"
= 512
"
11 12

Publicité

Table des Matières
loading

Table des Matières