760 Series Common Features:
• Large numbers and symbols displayed
• TightSight™ bottom display
• Visual and selectable audible indication
when voltage is present
• Measures 660 AAC Current (61-763)
• Measures 660A AC/DC Current (61-765) • Protective rubber boot
• Measures AC/DC Voltage, Resistance &
Capacitance
• Audible continuity
• Bright, bold backlight
Model Specific Features:
• 61-763 and 61-765 models are true rms sensing, measures AC/DC voltage, capacitance, AC
current and frequency
• Both models employ a High Frequency Reject (HFR) circuit to filter noise or help in
making accurate measurements on complex wave shapes like
those found on Adjustable Speed Drives (ASDs)
• 61-765 model is true rms sensing and measures
DC current
Features
1. Tapered jaws w/hook tip
2. Lever
3. Function Dial
4. Main Display (LCD)
5. Volts and resistance (V-Ω)
input terminal
6. Common (COM) input terminal
7. TightSight™ bottom display
8. Protective rubber boot
9. Measuring Functions
10. High Voltage (Hi-V) warning
11. Data & Peak Hold
12. Max/min
13. Relative (61-763)
Relative/Zero (61-765)
14. Backlight
15. Capacitance (
) / Frequency (Hz)
• Peak, max/min, data hold
• Selectable Auto power off and low
battery indicator
• Tapered jaws for reaching into tight spaces
• Hook tip for easier wire separation
• Electronic overload protection on
all ranges
• Cat IV-600V/Cat III-1000V
1
10
2
3
9
14
12
15
13
4
6
5
8
7
3
Symbols on the Unit
Warning - read the instruction manual
Cat IV - 600V Safety category
Cat III - 1000V Safety category
Main Display Icons
17. 9999 count display
18. AC measurement
19. DC measurement
20. Polarity indicator for DC
21. Auto Power Off
(APO)
22. Hold
23. Min/Max
24. Peak
25. Audible continuity
26. Relative
27. Volts/Amps
28. Farads
29. Hertz/Ohms
30. Low battery indicator
TightSight™ Display Icons
31. 9999 count display
32. Polarity indicator for DC
33. DC measurement
11
34. AC measurement
35. Amps
APO HOLD MAX MIN P + P -
mVA
AC
nmµF
DC
kMΩ
Hz

Main Display

23
22
17
21
18
20
19
33 34
35
DCAC AMPS
31
32
4
24
26
30
27
28
29
25