Convergence - Sony TRINITRON KV-13FS100 Instructions De Service

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2-2. CONVERGENGE
Before starting convergence adjustments:
1 Perform FOCUS, VLIN and VSIZE adjustments.
2. Set BRIGHTNESS control to minimum.
3. Feed in dot pattern.
2-2-1. VERTICAL STATIC CONVERGENCE
1. Adjust V. STAT magnet to converge red, green and blue dots in the
center of the screen (Vertical movement adjust S V.STAT RV1750
to converge).
Center dot
RV1750
R
B
G
V.STAT
2. Tilt the V. STAT magnet and adjust static convergence to open or
close the V. STAT magnet.
When the V. STAT magnet is moved in the direction of arrow a and
b, red, green, and blue dots move as shown below:
1
a
b
b
2
a
3
b
R
G
B
V.STAT magnet
a
b
B
B
G
G
R
R
a
R
G B
b
b
B G R
a
b
a
R
B
G
G
b
R
B
2-2-2. HORIZONTAL STATIC CONVERGENCE
If the blue dot does not converge with the red and green dots, perform
the following:
1. Move BMC magnet (a) to correct insuffi cient H.Static convergence.
2. Rotate BMC magnet (b) to correct insuffi cient V.Static convergence.
3. After adjusting the BMC magnet, repeat Beam Landing Adjustment.
PURITY
— 12 —
KV-13FS100/13FS110/14FV300
b
BMC magnet
a
V.STAT