MONITORS PROGRAMMING
P
rogramming the Tekna R5 monitors.
REMEMBER: Monitors only need to be programmed when they
are installed in parallel or when there are general door panels.
Locate the configuration dip switch on the back of the door panel
and set switch number 2 to ON.
The door panel will emit a tone to advise that the system has
entered into programming mode.
In systems with more than one door panel, the programming
process shall be done on the master door panel only.
Master
Each apartment must have one master unit only; in case of parallel units configure
them as slaves, whether they are monitors or telephones.
Turn off the monitor to be programmed by holding
pressed the door release push button for one second.
Once off, press the autoswitch-on push button.
While holding pressed the autoswitch-on push button,
simultaneously press the door release push button.
To show that the system is ready for programming, the
door panel will emit a tone and the image will
appear on the monitor. The push buttons can now
be released.
Lift the handset off the monitor.
With the handset lifted:
If programming the monitor as master, replace
If programming it as slave, press the door release
Slave
Make a call to check that the monitor has been successfully programmed.
Repeat these steps to program the rest of monitors.
Once the programming has finished, set the programming switch to OFF.
If you don't, the door panel will reproduce a sound to advise that the
system is still into programming mode.
Press the door panel push button.
At this moment both door panel
and handset will emit tones.
the handset.
push button, then replace the handset.