FUSE REPLACEMENT

SWITCH OFF THE ELECTRICITY SUPPLY.
Remove the grease filters.
Remove the electrical box support and open
the electrical box.
Replace with the same type of fuse (5x20mm,
5A, 125V).
ELECTRICAL
BOX
- 11 -
FUSE
ELECTRICAL
BOX
SUPPORT