PARAMÈTRE
P06
P07
P08
P09
P10
P11
32
Gazania 3.25/25 - Version 1 du 21/06/2017
2. MISE EN SERVICE
DESCRIPTION
TEMPORISATION POST-CIRCULATION SANITAIRE
(NON APPLICABLE AU MODÈLE BI THERMIQUE)
CE PARAMÈTRE PERMET DE RÉGLER LA DURÉE DE
FONCTIONNEMENT DE LA POMPE, EN SANITAIRE,
APRÈS LA FERMETURE DU ROBINET.
FONCTION PROTECTION COUP DE BÉLIER
UNE FOIS QUE CETTE FONCTION EST ACTIVÉE, LE
CONTACT SANITAIRE EST RETARDÉ PENDANT UN
TEMPS ÉGAL À LA VALEUR ENTRÉE
TEMPORISATION CHAUFFAGE
CE PARAMÈTRE PERMET DE RÉGLER LE RETARD DE
DÉPART DE LA CHAUDIÈRE, EN CHAUFFAGE, APRÈS
L'EXTINCTION DU THERMOSTAT D'AMBIANCE.
RÉGLAGE DE LA TEMPÉRATURE DE CHAUFFAGE
DANS LE CAS OÙ LA CHAUDIÈRE EST INSTALLÉE
DANS
LE
CADRE
D'UN
CIRCUIT
TEMPÉRATURE, INSTALLER UN THERMOSTAT DE
SÉCURITÉ SUR LE DÉPART CHAUFFAGE, QUI PEUT
STOPPER L'ACTIVITÉ DE LA CHAUDIÈRE EN CAS DE
TEMPÉRATURE ÉLEVÉE. LA SOCIÉTÉ N'ASSUME
AUCUNE RESPONSABILITÉ POUR LES DOMMAGES
CAUSÉS AUX PERSONNES OU POUR DÉFAUT DE SE
CONFORMER À CES INSTRUCTIONS.
TEMPORISATION POST-VENTILATIONMEDIANTE
CE PARAMÈTRE PERMET DE RÉGLER LA DURÉE
DE FONCTIONNEMENT DU VENTILATEUR, APRÈS
L'EXTINCTION DU BRÛLEUR.
SÉLECTION DU TYPE DE CHAUDIÈRE
INTERVALLE
000 - 090
000 - 003
000-199
000 - 001
À
BASSE
003-200
000 - 003
FONCTION
VALEUR EXPRIMÉE EN MULTIPLES DE 5
SECONDES
(PRÉRÉGLÉE À 18 X 5 = 90 SECONDES)
000 = DÉSACTIVÉE
VALEUR ÉXPRIMÉE EN SECONDES
(PRÉRÉGLÉE À 2 SECONDES)
000 = DÉSACTIVÉ (PRÉRÉGLÉ DE SÉRIE)
VALEUR EXPRIMÉE EN SECONDES
000 = STANDARD (30-80° C)
(PRÉRÉGLÉE DE SÉRIE)
001 = RÉDUITE (25-45°) POUR LES
INSTALLATIONS AU SOL
VALEUR EXPRIMÉE EN MULTIPLES DE 3
SECONDES
(PRÉRÉGLÉE À 4 X 3 = 12 SECONDES)
000 = BITHERMIQUE
001 = INSTANTANÉE MONOTHERMIQUE
002 = CHAUFFAGE SEUL
003 = ACCUMULATEUR