PL2500
Suitable for small entrances
GB
.... 16
FR
.... 20

Publicité

Table des Matières
loading

Sommaire des Matières pour Frico PL2500 Serie

  • Page 1 PL2500 Suitable for small entrances ..16 ..20...
  • Page 2 PL2500 1025 / 1535 / 2025 min 500 Cu ø15 min 500 min 500 min 500 min 500 Fig.1 ø17,5 ø17,5 Gland Gland Knock-out ø32,5 ø25,5 Knock-out Gland ø20,5 Knock-out ø17,5 Fig.2...
  • Page 3 PL2500 TX20 Fig.3: Open the unit.
  • Page 4: Minimum Distance

    PL2500 Minimum distance Fig.4: Minimum distance.
  • Page 5 PL2500 Mounting with wall brackets ø8 (3x) ø5 ø10 PL2510 2 pcs PL2515 2 pcs PL2520 3 pcs Fig. 6: Mounting with wall brackets Fig. 6: Mounting with wall brackets...
  • Page 6: Accessories

    PL2500 Accessories PA34TR15 PL2510, PL2515, 1 m PL2520, 1 m PA34TR20 PA2P15 PL2510, PL2515, 1 m PA2P20 PL2520, 1 m PL2510, PL2515 PA2PF15 PA2PF20 PL2520 PAMLK PL2500 PL2500 W PAWAK FHDN15 PL2500 W PA2P PA34TR PA2PF PAMLK PAWAK FHDN15...
  • Page 7 PL2500 Accessories PLSB PLSAC PLSRTX 673 09 22 70x33x23 mm PLSB PLSUR 673 09 21 114x70x50 mm PLSUR CC603 673 09 23 CC605 673 09 24 CC610 673 09 25 10 m CC615 673 09 26 15 m PLSAC 673 09 27 30 m CC403 CJ4/CJ6...
  • Page 8 PL2500 PL2510E08/ PL2515E12/ PL2520E16 SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Page 9 PL2500 PL2510WA/ PL2515WA/ PL2520WA SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Page 10 PL2500 PAMLK, motor alarm card SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo N F1 F2 F3...
  • Page 11 PL2500 PLS Basic PL2500A PL2500E PLSRTX PLSUB1 SIReUB1 SIReRTX PLSB2 SIReB1/B2/B1EC (optional) 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY CC6XX SIReCC6XX L=2m (max 50 m) CC6XX (max 10 m) SIReCC6XX (max 50 m) PLSB2 SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY CC6XX SIReCC6XX...
  • Page 12 PL2500 PLS Basic PL2500W PLSUB1 PLSRTX SIReUB1 SD230 SIReRTX PLSB2 SIReB1/B2/B1EC (optional) 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY CC6XX SIReCC6XX L=2m (max 50 m) L=1,5m CC6XX (max 10 m) SIReCC6XX (max 50 m) SD230 PLSB2 SIReB1/B2/B1EC 230V~ ROOM Pot.
  • Page 13 PL2500 Output charts Supply water temperature: 110 °C Water temperature: 110/80 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output * Outlet Water Pressure position water flow drop air temp.
  • Page 14 PL2500 Output charts Supply water temperature: 60 °C Water temperature: 60/40 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +32 °C Type Airflow Output Return Water Pressure Output * Outlet Water Pressure position water flow drop air temp.
  • Page 15: Technical Specifications

    PL2500 Technical specifications PL2500 A ambient, no heat Type Output Airflow* Sound Voltage Amperage Length Weight level* motor motor [kW] [dB(A)] [mm] [kg] PL2510A 900/1300 43/53 230V~ 1026 1250/2100 44/54 230V~ 1536 23,5 PL2515A PL2520A 1800/2600 44/55 230V~ 2026 PL2500 E with electrical heat ∆t Type Output...
  • Page 16: Généralités

    Consignes de montage et mode d'emploi Généralités Montage Lisez attentivement les présentes consignes Le rideau d'air est monté horizontalement, avant l'installation et l'utilisation. Conservez avec la grille de sortie vers le bas aussi près ce manuel à des fins de consultation que possible de la porte.
  • Page 17 Connecté via le circuit imprimé PLS avec Noter que l'appareil doit être précédé d'une cordon de 1,5 m et fiche. vanne de régulation ; voir le kit vannes Frico. La batterie à eau est raccordée sur le haut Appareil avec chauffage électrique de l'appareil par un tube de cuivre lisse de L'installation électrique est effectuée sur...
  • Page 18: Entretien

    Entretien, réparations et maintenance Surchauffe Opérations initiales pour toute intervention Le modèle à chauffage électrique est doté d'un d'entretien, de réparation et de maintenance: dispositif anti-surchauffe. Si ce dispositif se 1. Déconnecter l'alimentation électrique déclenche, il convient de le réinitialiser de la 2.
  • Page 19 Remplacement de la batterie à eau chaude. Disjoncteur à courant résiduel (E) 1. Couper l'alimentation d'eau de l'appareil. Si l'installation est protégée par un 2. Déconnecter les canalisations de la disjoncteur à courant résiduel, et que ce batterie à eau chaude. dernier se déclenche à...
  • Page 20 Technical Support - tel. +46 313368600 Art.no.208876, 2015-02-18 CH...