OPERATION INSTRUCTIONS
LEAK CHECK
• Perform all leak tests outdoors.
• Extinguish all open flames.
• NEVER leak test when smoking.
• Do not use the fire pit until all connections have been leak tested and do not leak.
Hose/Regulator
connection
1. Make 2-3 oz. of leak check solution (one part liquid dishwashing detergent and three
parts water).
2. Put leak solution in a spray bottle.
3. Make sure cylinder valve and control valve are OFF.
4. Apply several drops of solution where hose attaches to regulator.
5. Apply several drops of solution where regulator connects to cylinder.
6. Turn cylinder valve ON.
If bubbles appear at any connection, there is a leak.
1. Turn cylinder valve OFF.
2. If leak is at hose/regulator connection: tighten connection and perform another leak test.
If bubbles continue appearing, the hose should be returned to the place of purchase.
3. If leak is at regulator/cylinder valve connection: disconnect, reconnect, and perform
another leak check. If you continue to see bubbles after several attempts, cylinder valve
is defective and should be returned to cylinder's place of purchase.
If NO bubbles appear at any connection, the connections are secure.
Note: Whenever gas connections are loosened or removed, you must perform a complete
leak test.
Complete installation.
WARNING
Regulator/Cylinder
connection
NEVER USE A LIGHTER/FLAME TO CHECK FOR
GAS LEAKS.
DANGER
18