Note
This service and repair work should only be carried out by a suitably qualified electrician (with specialist training, knowledge and
experience, and recent related work experience) in accordance with all appropriate local and national safety regulations.
Servicing, modification, testing and maintenance of electrical appliances should only be carried out in accordance with all appropriate
legal requirements, accident prevention regulations and valid standards. All regulations of the appropriate utility supply companies and
standards relating to safety (not limited to electrical safety) are to be complied with.
Note
Service and repair work on gas machines should only be carried out by suitably qualified persons in accordance with all appropriate local
and national safety regulations. Ensure all special regulations applying to gas installations are also complied with.
Before starting any service work, the machine must be disconnected from the gas supply.
Danger!
Even with the machine switched off, voltage may be applied to some components.
Before starting any service work, the machine must be disconnected from the power supply. Suitable measurements must be made to
ensure that this is the case.
A general visual check and risk evaluation should always be carried out.
Incorrect conversion or service work can be dangerous (risk of fire, electric shock, etc.).
Danger!
Correct grounding function can be deactivated if casing parts are incorrectly assembled.
Correct grounding function must be ensured when reinstalling the casing.
Carry out appropriate electrical safety checks.
Danger!
During installation, all accessible conductive parts that are not connected to ground must not have any link to ground (strengthened
double insulation).
To confirm this, insulation resistance and touch current measurements must be carried out.
09.08.2011
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
Designation
Installation kit MF01 10 20 multifunction module PW 6xx7, liquid dispensing 1-6
Installation kit MF02 10 20 multifunction module PW 6xx7, liquid dispensing 7-12
Installation kit MF03 10 20 multifunction module PW 6xx7, liquid dispensing 7-11
and water recycling (WRG)
Installation kit MF05 10 20 multifunction module PW 6xx7, liquid dispensing 1-3
and water recycling (WRG)
DOS-P2 dispenser pump
DOS-R non-return valve
DOS-G2 dispenser pump housing for maximum 3 dispenser pumps
DOS-S dispenser pump stand for maximum 3 dispenser pumps
M.-Nr. 09149680

Publicité

loading

Ce manuel est également adapté pour:

Mf01 20Mf02 10Mf02 20Mf03 10Mf03 20Mf05 10 ... Afficher tout