Produktgruppe 512
39 von 40
Arrange and connect the wiring harnesses:
Warning!
The load and control current wiring harnesses should be separated from one another to prevent noise in the control circuit
(electromagnetic tolerance).
Extra wiring should be laid in the opposite direction to avoid antenna-like behavior.
Connect load current wiring harness 20X-41X from module 2 (liquid dispensing 7-12) EZL 235
1-6) EZL 235
ST9; see Fig. 2, Pos. 3a.
Connect control current wiring harness N1Q_ST112, N1Q_ST11 from module 2 (liquid dispensing 7-12) EZL 235
1 (liquid dispensing 1-6) EZL 235
Connect electronics ELZ 235 module 2 and ELZ 235 module 1 in accordance with the wiring diagram.
Connect the coded plugs:
Connect coded plug MFM 2-5 to module 2 (liquid dispensing 7-12) EZL 235
Register module 2 (liquid dispensing 7-12):
Service Settings Register module EZL with coding 2 Register module? OK Diskette symbol to save the registration.
Switch on dispensing display.
Service Settings Basic settings Dispensing Dispensing display: Off
symbol to save display activation.
Note
Switching on the dispensing display enables the operator to select and deselect dispensing. Without dispensing display, only
information regarding whether dispensing is active and the dispensing amount is shown.
To quit service mode, switch the machine off.
Connect and calibrate the dispensing pump:
Knock out the pre-punched hole on the machine rear panel.
Install the cable guide on the rear panel; see Fig. 3.
Connect the dispensing pump in accordance with the wiring diagram.
If dispensing pump capacity is known, this value can be entered directly in the operator level (e.g., dispensing pump 7).
Operator level Main menu Settings Dispensing pump capacity Dispensing pump 7: No .....ml/min OK Back (until
diskette symbol appears) Diskette symbol to save the capacity.
If dispensing pump capacity is not known, the dispensing pump should be calibrated in the operator level (e.g., dispensing pump 7).
Operator level Main menu Settings Dispensing calibration Dispensing pump 7.
Place the dispensing pump's suction hose in a container with a fill line.
Fill the container to the fill line.
Press the 0/1 button (dispensing pump will run for 60 seconds).
Use a beaker or measuring cup to refill the container to the fill line.
Determine the dispensed amount in the beaker/cup and enter it in the display (V:.....ml).
Press the diskette symbol to save the dispensed amount.
Register the refill message (e.g., dispensing pump 7).
Operator level Main menu Settings Dispenser refill message Dispensing pump 7: No
one level) Diskette symbol to save the refill message.
Check dispensing in all programs and adjust as necessary.
Carry out a functional check.
Back up all data via service mode.
Service Backup Backup data for EW Overwrite existing data? Diskette symbol to overwrite EW data.
To quit service mode, switch off the machine.
Finish up:
Re-install the machine lid.
Carry out a safety check.
Reconnect the machine to the electrical and gas supplies and switch it on.
am
10.02.2012
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
ST112; see Fig. 2, Pos. 3b.
Umbau- und Montageanweisung
M.-Nr. 09087210
ST10 to module 1 (liquid dispensing
ST3, pin 2-5; see Fig. 2, Pos. 4.
On OK Back (to go back one level) Diskette
Yes OK Back (to go back
ST111 to module