Troubleshooting
Problem
Motor is not functioning
Motor moves in the wrong
direction
The i-R Receive Connect
does not execute manual
control commands
The i-R Receive Connect
does not execute automatic
control commands
Cause
Faulty connection
Faulty connection
Transmitter is not
programmed
Alarm signal is active
Transmitter is not program-
med
Alarm signal is active
The i-R Receive Connect is
set to manual mode
Solution
Check the connection
Exchange
and
in the power supply unit or
change the direction of
motion (see page 35)
Programme transmitter
Await alarm signal or
eliminate
Programme transmitter
Await alarm signal or
eliminate
Set the i-R Receive Connect
by using a learnt in hand-
held transmitter into auto-
matic mode
wires