C� Configuration description:
Time [s]:
Parameter Number
1 ( TIME )
Duration of light after motion detection.
Light threshold [lx]:
Parameter Number
2 ( LIGHT )
0 – run Learn ambient light sequence.
2000 - is used as daylight ( always night mode ).
Motion Radar Sensitivity [%]:
Parameter Number
5 ( SENSITIVITY )
Brightness measuring interval [min]: ( only SLAMP or STOGGLE )
Parameter Number
6 ( BRIGHTNES MEAS INTERVAL ) 1
Interval for measuring ambient light when lamp is on ( lamp switches off briefly and
measures ). 0 = function is off.
Use external Ambient Light Value:
Parameter Number
8 ( GLOBAL_LIGHT )
When GLOBAL_LIGHT mode is ON – device overrides its own light sensor values
and uses Light report values from any Z-Wave light sensor instead – this has to be
configured appropriately to send light automatically.
If the last remote light level value is older than 30 minutes, the internal light value is
used again until the next external value is received.
Disable local control:
Parameter Number
9 ( SLAVE_MODE )
Size
Range
Default
2
5-900
180
Size
Range
Default
2
2-2000, 0
2000
Size
Range
Default
1
2-100
100
Size
Range
Default
5-120, 0
0
Size
Range
Default
1
0/1
1
Size
Range
Default
1
0-4
2
- 38 -
Bit Field:
Bit
7
6
5
4
3
2
Function -
-
-
-
-
"Stupid" mode Central unit
"Stupid" mode ( bit 2 = 1 ):
- has higher priority then slave mode.
- LED is permanently on ( for simple power wall switch controlling ).
Slave mode ( bit 0 = 1 ):
- only if included in Z-Wave network
- useful for controlling via third-party sensor
- LED is directly controlled via Z-Wave, internal sensors are not used for controlling it
Central unit checking ( bit 1 = 1 ): ( useful especially for controlling via gateway )
When slave bit is 0:
- device signalises fail of lifeline connection ( if this bit is zero, fail of lifeline connec-
tion is not signalised )
When slave bit is 1:
- device checks presence of Z-Wave device in lifeline group ( gateway ). If it is not
present for 2 minutes ( testing repeatedly every 30 seconds ) device switches
to normal mode in the same way as after the end of local disabled mode
( ON_BEHAVIOUR )
- the device checks every 1 minute for recovery of Lifeline connection.
- if no lifeline specified - it works in normal mode
Be careful with this option, device stops using its own motion sensor in Slave
and Stupid mode.
Off behaviour ( timeout ):
Parameter Number
10 ( OFF_BEHAVIOUR )
Behaviour after BASIC OFF ( and similar commands ).
If a transition ( even with zero change ) with a non-default duration is to be pro-
cessed, the transition cannot be interrupted by any motion event in any case.
1
0
Slave mode
checking in
slave mode
Size
Range
Default
2
0 – 209, 255
10
- 39 -