PRODUCT DESCRIPTION 
Intended use 
BioPlus 50/100/200,  referred  to  in  the  following 
as  "unit", may only be  used as specified in the 
following: 
• BioPlus: Water filtering and recirculation
• Operation under observance of the technical data.
The following restrictions apply to the unit: 
• Only use indoors and for aquaristic purposes in the
home (not for commercial use). 
• Only operate with water at a water temperature of
+39 °F to +95 °F.
Function description 
 B 
Path of the water: Drawn in by a pump into the pump
unit,  the  water  flows  through  the  filter  modules,  ar‐
ranged above each other in stages to  form the filter 
unit. Each filter module is equipped with a foam filter and/
or filter fleece (top filter module). The water en‐ters the 
filter module through the inlet on the side and exits 
through the small flow‐out nozzles or the central outlet, 
depending on the position of the outlet control knob. 
 
INSTALLATION AND CONNECTION 
N O T E  
Ensure that the pump never runs dry! 
Possible consequences: The pump will be destroyed. 
Protective measure: Regularly check the water level in 
the aquarium. 
 
TROUBLESHOOTING
Malfunction 
The unit does not start up 
Water flow insufficient 
Insufficient filtering performance Foam filter or filter fleece soiled 
Cause 
No mains voltage 
Impeller unit blocked 
Filter housing or impeller unit soiled 
Impeller unit worn 
Central outlet or flow‐out nozzles soiled 
Foam filter or filter fleece soiled 
Foam filter or filter fleece worn 
Filter housing clogged 
N O T E  
Thoroughly rinse out all filter material with warm tap 
water before using for the first time in order to remove 
any soiling. (→ Cleaning or replacing the filter media) 
 
 C, D, B 
The supplied suction cups serve for fastening the unit 
to a clean, smooth surface. 
 Push  the  suction  cups  into  the  mounting  holes  of
the pump unit with a twisting movement. 
– Pay  attention  to  the  alignment  of  the  tab  (it
should point upwards or to the side). 
 Fasten the unit in a corner of the aquarium: Ensure
that the flow‐out nozzles are just below the surface
of the water. 
COMMISSIONING/START‐UP 
 D, B 
• Route  each  power  connection  cable  such  that  it 
forms a drip loop.
Switching on: Connect the unit to the mains. The unit 
switches  on  immediately.  When  the  unit  is  switched 
on, it takes several minutes for the air to escape from 
the unit (this makes a noise). 
 Use the outlet control knob to determine which wa‐
ter  outlet  is  used  (central  outlet  or  flow‐out  noz‐
zles). 
Switching off: Disconnect the unit from the mains. 
Remedy 
Check the mains voltage. 
Clean 
Clean 
Replace impeller unit 
Clean 
Clean 
Clean 
Replace 
Clean the filter housing. 
‐  EN  ‐ 