Symbols used in these instructions
N O T E
Indicates information intended to give the user a bet‐
ter understanding.
Additional information
A Reference to a figure, e.g. Fig. A.
PRODUCT DESCRIPTION
Intended use
BioPlus 50/100/200, referred to in the following
as "unit", may only be used as specified in the
following:
• BioPlus: Water filtering and recirculation
• Operation under observance of the technical data.
The following restrictions apply to the unit:
• Only use indoors and for aquaristic purposes in the
home (not for commercial use).
• Only operate with water at a water temperature of
+39 °F to +95 °F.
Function description
B
Path of the water: Drawn in by a pump into the pump
unit, the water flows through the filter modules, ar‐
ranged above each other in stages to form the filter
unit. Each filter module is equipped with a foam filter and/
or filter fleece (top filter module). The water en‐ters the
filter module through the inlet on the side and exits
through the small flow‐out nozzles or the central outlet,
depending on the position of the outlet control knob.
INSTALLATION AND CONNECTION
N O T E
Ensure that the pump never runs dry!
Possible consequences: The pump will be destroyed.
Protective measure: Regularly check the water level in
the aquarium.
TROUBLESHOOTING
Malfunction
The unit does not start up
Water flow insufficient
Insufficient filtering performance Foam filter or filter fleece soiled
Cause
No mains voltage
Impeller unit blocked
Filter housing or impeller unit soiled
Impeller unit worn
Central outlet or flow‐out nozzles soiled
Foam filter or filter fleece soiled
Foam filter or filter fleece worn
Filter housing clogged
N O T E
Thoroughly rinse out all filter material with warm tap
water before using for the first time in order to remove
any soiling. (→ Cleaning or replacing the filter media)
C, D, B
The supplied suction cups serve for fastening the unit
to a clean, smooth surface.
Push the suction cups into the mounting holes of
the pump unit with a twisting movement.
– Pay attention to the alignment of the tab (it
should point upwards or to the side).
Fasten the unit in a corner of the aquarium: Ensure
that the flow‐out nozzles are just below the surface
of the water.
COMMISSIONING/START‐UP
D, B
• Route each power connection cable such that it
forms a drip loop.
Switching on: Connect the unit to the mains. The unit
switches on immediately. When the unit is switched
on, it takes several minutes for the air to escape from
the unit (this makes a noise).
Use the outlet control knob to determine which wa‐
ter outlet is used (central outlet or flow‐out noz‐
zles).
Switching off: Disconnect the unit from the mains.
Remedy
Check the mains voltage.
Clean
Clean
Replace impeller unit
Clean
Clean
Clean
Replace
Clean the filter housing.
‐ EN ‐