Digital Laser Measure
Measuring range (typical)
Measuring range (typical,
unfavorable conditions)
Measuring accuracy (typical)
Measuring accuracy (typical,
unfavorable conditions)
Lowest indication unit
Indirect Distance Measurement
and Vial
- Measuring range
Gradient measurement
- Measuring range
- Measuring accuracy (typical)
- Lowest indication unit
Operating temperature
Allowable charging
temperature range
Storage temperature
Relative air humidity, max.
Laser class
Laser type
Laser beam diameter at 77° F (25 °C)
- at 32 ft (10 m) distance, approx.
- at 328 ft (100 m) distance, approx.
Automatic switch-off after approx.
- Laser
- Measuring Tool
Weight
Dimensions
2610050173 04-18 GLM400CL.indd 19

Technical Data

+14° F to 113° F (-10° C to +45° C)
-4° F to 158° F (-20° C to +70° C)
5.5 (6.9) x 2.5 x 1.1 in (142 (176) x 64 x 28 mm)
GLM400CL
3 in - 400 ft (0.08 –122 m
196 ft (60 m )
±1/16 in (±1.5 mm
±1/10 in (±3 mm )
1/32 in (0.5 mm)
0°–360° (4x90°)
0°–360° (4x90°)
±0.2°
41°F to 104°F (5°C to 40°C)
650 nm, <1mW
.35 in (9 mm)
3.5 in (90 mm)
Adjustable
.46 lb (0.21 kg)
A)
)
A)
)
C)/D)/H)
0.1°
E)
90 %
2
20 s
G)
19