SYSTEM CHARACTERISTICS
Audio system with 2 wires installation.
Weatherproof (IP-44) and vandal resistant (IK-09) door panel.
Just 1 TF-104 transformer (12Va.c., 1.5A).
Electronic call with acoustic acknowledgement signal.
a.c. lock releases activation.
Telephone with call reception volume control and additional push button (T-922).
SYSTEM OPERATION
To make a call the visitor should press the push button corresponding to the apartment he wishes
to contact. An acoustic tone will be heard confirming the call as the push button is pressed. At
this moment the call will be received at the telephone in the dwelling.
To establish communication pick up the telephone handset.
To open the door, press the door release push button at any moment.
STARTING RECOMMENDATIONS
Do not use excessive force when tightening the transformer connector screws.
Install the equipment without the power connected. Disconnect from power before any system
modification. Check that the input voltage is lower than 230Va.c.
Before to connect the system, check the connections between door panel and telephones, and
the transformer connection. Do always follow the enclosed information.
13
14
I
nstalling the TF-104 transformer.
3,5 x 25
DIN-7971
The transformer can be installed on a DIN guide (3 units) simply pressing it.
To disassemble the transformer from the DIN guide, use a plain screwdriver to lever
the flange as shown on the picture.
E
mbedding box positioning.
1650
The upper part of the door panel should be placed at 1,65m. height roughly. The hole dimensions
are:
The door panel has been designed to be placed under most of the environmental conditions.
However it's recommended to take additional cautions like rainproof covers.
POWER SUPPLY INSTALLATION
The transformer must be installed in a dry and
protected place. It's recommended to protect
3,5 x 25
the transformer by using a thermo-magnetic
DIN-7971
circuit breaker.
To install the transformer directly on the wall,
insert the fixing flanges.
Drill two holes of Ø6 mm. and
insert the wallplugs.
Fix the transformer with the specified
DIN 46277
screws.
DOOR PANEL INSTALLATION
1850
1450
131(An) x 131(Al) x 45(P) mm.