• Connect the output of the power supply unit
(12 V DC) to the solenoid valve.
• Fasten the cable so that it does not drop into the
water-bearing area under the solenoid valve.
6
Connecting the backpressure sensor
The backpressure sensor notifies the building
management system about backpressure in the
trap. If there is backpressure, the building
management system must initiate appropriate
actions; for example, triggering an alarm and
closing the solenoid valve.
Connection specifications for the switching output:
Designation
Value
Contact load
≤ 50 V DC / ≤ 500 mA DC
Type
Break contact (NC)
Rules for connecting the backpressure sensor:
• Connect the backpressure sensor switching
output to a digital input of the building
management system.
• The backpressure sensor switching output must
not be used to switch the solenoid valve.
• Fasten the cable so that it does not drop into the
water-bearing area under the solenoid valve.

Related documents

For maintenance and repair of the Geberit sanitary
flush without control, see maintenance manual
968.652.00.0.
9007203753511179-1 © 05-2020
968.650.00.0(01)