Maintenance; Removal Of Lime Scale Deposits; Door Gasket - Vulcan C24EO Serie Manuel D'installation Et D'utilisation

Table des Matières

Publicité

: The steamer and its
parts are hot. Use care when operating,
cleaning or servicing the steamer. The
cooking compartment contains live steam
and hot water. Stay clear when opening
the door.
Steamer must be cleaned daily. See CLEANING
section.

REMOVAL OF LIME SCALE DEPOSITS

: Read and follow the
instructions on the deliming material
package. Avoid contact with skin and eyes.
Wear plastic or rubber gloves and safety
goggles when handling. Wash thoroughly
after handling. If deliming solution comes
in contact with the skin or eyes, rinse
thoroughly with clean water.
: The steamer and its
parts are hot. Use care when operating,
cleaning or servicing the steamer. The
cooking compartment contains live steam
and hot water. Stay clear when opening
the door.
The steamer should be delimed when scale
is present in the cavity well. Deliming may be
required frequently depending on water quality
and scale build up. This is in accordance with
the minimum preventive maintenance schedule
required by warranty.
Items required (not provided):
1. Deliming Solution – Scale Release™
Part Number 854893-13 (qty. 1).
Contact the local Authorized Vulcan
Servicer or refer to website www.
vulcanequipment.com

MAINTENANCE

2. Plastic or rubber gloves.
3. Safety goggles or face shield.
4. Spray bottle.
5. 1-gallon container for mixing the deliming
solution.
NOTE: Deliming solution may cause the surface
Procedure:
1. Turn steamer off. Drain the steamer.
2. One bag will treat a C24EO3 or C24EO5
steamer.
3. Spray cavity walls with solution. Pour solution
into cavity well.
4. Fully depress Power Switch to ON
and set Timer for 5 min. After timer sounds,
rotate Timer dial to OFF position and fully
depress Power Switch to OFF
5. Let delime solution soak for a minimum of
30 minutes, maximum 60 minutes. If scale
is still present, repeat steps 1 through 5.
6. Drain the steamer and rinse thoroughly with
warm clean water.
7. Dry with a clean dry cloth.
8. Leave steamer door open when not in use.
If the door gasket is leaking due to a nick or
cut, it must be replaced. Damage to the gasket
sealing surface will cause steam leakage.
— 17 —
C24EO SERIES STEAMER
of aluminum measuring tools to tarnish
or etch.
1 bag to 2 gallons warm water
Maximum steamer capacity 3 gallons

DOOR GASKET

position
position.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

C24eo3C24eo5Ml-136006Ml-136007

Table des Matières