Dometic Interact Manuel D'utilisation page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation
11 AGS Screen
12
From this screen, you can control and monitor the
following functions:
• Auto Charger: Use this toggle button to enable or
disable the auto charger. The auto charger is disabled
by default. When you enable the auto charger, a pop-
up message appears.
12 Ventilation Alert
The AGS becomes disabled if the ignition is turned on.
If you attempt to enable the auto charger while the
ignition is on, a pop-up message appears.
13 Ignition Alert
The following auto charger settings are available:
– Time Selection: Use the available tumblers (hour
and minute) to set the desired quiet time start and
end times. The generator is turned off automatically
during the specified quiet time.
– Start Voltage: Use the tumbler to set your desired
voltage setting (10 V–12.9 V). The default setting is
10.5 V. The Start Voltage tumbler controls the
threshold voltage under which the AGS must turn
on.
– Time Under: Use the tumbler to set your desired
timer setting (0–10 min). The Time Under tumbler
specifies the timer delay before the AGS starts,
when the system drops below the set threshold
voltage.
• AGS Climate: These options enable the climate
controls, which run the air conditioner and heat pump
of the generator when no shore power is available.
Dometic Interact
EN

Publicité

Chapitres

Table des Matières
loading

Table des Matières