LOADING TEST:
Drive a vehicle, whose weight does not exceed the maximum lifting capacity, on the
platform.
Put the rubber buffer on the platforms.
Press the 'UP' button, lift the platforms and pay attention to the synchronization and the
fluidity of the lift.
Check that there is no leakage in the hydraulic oil line.
When starting the load test no person or other material must be located below or close to
any of the moving parts of the lift.
Check and make sure that there is no leakage on the hydraulic circuit.
If an anomaly occurs, press the «EMERGENCY STOP» button to stop it immediately.
After removing the obstacles, repeat the test.
OPERATION
Only qualified and trained personnel are permitted to carry out this operations. Check
the procedures as follows.
Operating alerts:
Before any operation, remove any obstacles from the lifting area of the lift.
When lifting or lowering, no operator is permitted to remain in the lateral area of the
machinery, underneath it or on both platforms.
Avoid lifting vehicles exceeding the maximum permissible lifting weight.
When the vehicle is positioned on the platforms, make sure that the car body is resting
on the rubber pads supplied.
Take careful attention to the lifter's synchronization. If there are anomalies, stop each
operation in a timely manner, check and resolve the problem.
When the equipment is not used for a long period of time or overnight, the lift must be
lowered until it is completely closed, remove the vehicle and stop the power supply.
Instructions for the electronic drive: (see picture 24)