PE 6002
PE 6001
SCISSOR LIFT 3T DUAL CYLINDERS LOW RAISE
DOUBLE SCISSOR LIFT 3T

ADJUSTMENT

Add hydraulic oil as instructed.
After installing the elevator as shown in figure 4, having connected the hydraulic circuit /
electrical circuit and any pneumatic circuit, proceed as follows:
Open the hydraulic oil tank and add 12L of hydraulic oil H46 to it; The hydraulic oil is not
supplied by the manufacturer.
Make sure the hydraulic oil is free of impurities to prevent malfunctions to the solenoid
valve.
Turn off the photocell switch, setting it to «OFF».
Activate «MAIN SWITCH» to turn on the power, by clicking the «UP» button, check whether
the engine rotates clockwise (looking down), otherwise turn off the «MAIN SWITCH»,
then change the phase of the engine.
When power is switched on, the high voltage in the control unit is activated. Only
authorized personnel can do this.
Oil pressure adjustment:
1)
Press the «UP» button, then the engine starts to bring the platforms to the maximum
reachable height.
2)
Open the control unit door, press the «UP» and «SB4» button (as in the picture no. 21) for
a few minutes until the air flow is completely drained from the hydraulic circuit.
3)
Press the «DOWN» button until the platforms stop at the minimum permissible height,
press the «SECOND DOWN» button, this way the platforms will reach the closing position.
4)
The oil adjustment process is completed.
Picture 21 button