Installer Configurations; C1 Type Of Switchboard (Simplebus Top Mode) - Comelit 1998NV Manuel Technique

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installer configurations

Configurations
• System
• Services
This section is aimed at qualified technicians who,
after installing the product, will program the porter
switchboard using guided menus, which can be
viewed on the display by navigating the main menu.

C1 Type of switchboard (Simplebus Top mode)

The switchboard may be secondary or main.
• Set Simplebus when the switchboard is used as
secondary, as output from the LM-LM terminals
of switching devices Art. 1424 (Simplebus TOP
system); or when the switchboard is used in
Simplebus systems with switching devices Art.
1224A or in a system with a single riser and no
switching devices.
CAUTION! the secondary switchboard cannot be
configured as a switchboard in parallel.
• Set Simplebus top when the switchboard is used
as main in Simplebus top systems, then positioned
in the first section before the switching devices Art.
1424 which mark out the zones/risers.
The secondary or main switchboard must then be
configured as:
1- SINGLE
2- PARALLEL
3- SERIES.
1- Select single when the switchboard is the only one
in the system, or the only one serving a specific
riser.
2- If there are 2 main or secondary switchboards
serving the same riser, the parallelconfiguration
means that both switchboards will be operating
with the same functions.
The first of the two to answer a call will preclude
the possibility of the other one performing the
same procedure.
If one of the 2 devices is switched on or off, the
other will automatically follow suit.
Set the switchboard connected underneath the
LS-LS line of switching device Art. 1424 as Parall.
LS-IN; set the switchboard positioned underneath
62
System
Simplebus
Link
Single
Series master
Call
Simplebus
A/V
Audio
Back com.
FollowMe
Call repetition
Self Activation
Triple call
Help code
3- If there are 2 main or secondary switchboards
CAUTION!
- if
switchboards are not communicating correctly.
- if the ! icon appears, there is a configuration
problem with the 2 switchboards (e.g. both set as
Series master or slave, Parall. LP-IN or Parall. LS-IN
or one is in series and the other parallel).
- if in a Simplebus TOP system (with switching
devices Art. 1424), both main and secondary
switchboards are present; for correct system
operation the setting "C5- Backwards compatibility"
must be enabled on all switchboards.
Simplebus Top
Parall. LS-IN
Series slave
Indirect
Video
the LPin-LPin line of switching device Art. 1424 as
Parall. LP-IN.
For the parallel switchboard, switching to NIGHT
and the AUTO function is not possible (see "I9 Set
day mode").
A P should appear on the standby screen of the
two switchboards, indicating that the switchboard
is configured in parallel, in addition to the fixed
icon
.
serving the same riser, the series configuration
means that only 1 of the 2 can operate at one time
(Series master), while the other is disabled (Series
slave).
To change a switchboard from master to slave and
vice-versa, see "U11 How to activate or deactivate
the main switchboards".
An S should appear on the standby screen of the
two switchboards, indicating that the switchboard
is configured in series, in addition to the fixed icon
.
is flashing, this indicates that the 2
Parall. LP-IN