Error code and APP error description
Er01: Controller overcurrent. Abnormal working current. Check whether the pump is live or the controller is
defective.
Er02: Controller overheated. Check if the controller is exposed to sunlight or in a high temperature environment.
Er03: Pump is running dry or idling. Check the water level, clean the pump.
Er04: The pump blocked. The impeller stops running. Clean the impeller, bearings and pump. The impeller must
be able to turn freely.
Er05: Controller overvoltage. Abnormal working voltage. Check the input supply voltage.