Master / Slave Operation
Up to 32 units can be linked to operate in unison without a controller. Choose a master unit and set
dipswitch to either Auto or Sound Active mode. Set subsequent units in 'Slave' mode and use standard
XLR cable to link.
DMX Operation
Set units to run in DMX (Slave) Mode and assign a channel using the DMX Quick Reference Chart
included in this manual.
DMX Operation Guide
Channel
Function
1
Mode
2
Pattern Direction
3
Pattern Speed
4
Colour Selection
Specifications
Laser Output:
ORLASER105
ORLASER106
ORLASER107
Operational Modes:
DMX Control
Graphics & Effects
Input Power:
Power Consumption:
Dimensions (in):
Dimensions (mm):
Weight:
Value
0‐49
50‐99
100‐149
150‐255
0‐99
100‐199
200‐255
0‐255
0‐255
500mW@450nm Blue, 150mW@650nm Red, 50mW DPSS Green
600mW@450nm Blue, 150mW@650nm Red, 60mW DPSS Green
150mW@650nm Red, 50mW@532nm Green
DMX, Sound Active, Automatic
6 Channels (4 Channels ORLASER105)
Three Tunnel Laser with Multiple Patterns
AC 100‐250V 50/60Hz
15 Watts
8.7 x 7.1 x 3.4
220 x 180 x 85
3.9 lbs / 1.8kg
Description
Lasers Off
Sound Active
Auto Mode
DMX Mode
Clockwise
Stop
Counter Clockwise
Set Speed (Slow (0) to –fast (255))