How to proceed:
 F
1. Remove the screws for fastening the filter basket and remove the filter basket.
2. Screw the hose connector with union nut and seal onto the inlet.
3. Connect the hose with the stepped hose adapter and secure with a hose clip.
4. Screw the hose connector with union nut and seal onto the outlet.
5. Connect the hose with the stepped hose adapter and secure with a hose clip.
6. Fasten the pump to a suitable base using screws (not included in the scope of delivery).
Note!
Recommendations for hoses and pipes:
 Use 50 mm (2 ") hose connectors and hoses for a length of up to 5 m.
 Use DN 75 or DN 100 pipes for a length greater than 5 m.
Turning the pump casing
How to proceed:
 G
1. Remove the screws for fastening the filter basket and remove the filter basket.
2. Remove the screws for fastening the stand and remove the stand.
3. Remove the four screws for fastening the retaining plate and remove the retaining plate.
4. Remove the four screws and take off the pump casing.
5. Turn the pump casing, place it onto the motor and fasten with the four screws.
6. Fit the retaining plate onto the pump casing and fasten with the four screws.
7. Fit the stand and filter basket in the reverse order.
Start-up
Sensitive electrical components.
Possible consequences: The device will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
When started up, the pump automatically performs a pre-programmed self-test of approx. two minutes length (En-
vironmental Function Control (EFC)). The pump detects if it is running dry / blocked or submerged. The pump
switches off automatically after approx. 90 seconds if it runs dry (is blocked). In the event of a malfunction, disconnect
the power supply and flood the pump or remove the obstacle. Following this, the unit can be restarted.
Switching on: Connect the unit to the mains. The unit switches on as soon as the power connection is established.
Switching off: Disconnect the unit from the mains.
Seasonal Flow Control (SFC)
How to proceed:
 H
 Press and slide the switch.
– ON is indicated on the switch. The function is activated.
– ON is concealed on the switch. The function is deactivated.