Chimney Systems
Venting Components
Chimney Connector:
It is also known as
pipe or appliance pipe. The chimney
connector joins the appliance to the chimney. It must be a
7 inch (180mm) minimum diameter 24 gauge mild steel black
or 26 gauge blued steel, or an approved air-insulated double
wall venting pipe.
Thimble:
A manufactured or site-constructed device installed in
combustible walls through which the chimney connector
passes to the chimney. It is intended to keep the walls
from igniting. Site constructed thimbles must meet NFPA
211 Standards. Prefabricated must be suitable for use with
selected chimney and meet UL103 Type HT Standards. Follow
instructions provided by the manufacturer for manufactured
thimbles for masonry chimney and prefabricated chimneys.

Chimney:

The chimney can be new or existing, masonry or prefabricated
and must meet the following minimum requirements
in Section 5B.
Listed Termination Cap
Roof Brace (if required)
Trim Collar on
Inside Wall
Chimney
Connector
Floor
Protector
Figure 12.1 Prefabricated Exterior Chimney
Storm Collar
Flashing
Listed Chimney
Insulated " T "
Wall Support
Thimble
B. Chimney Systems
Prefabricated Metal Chimney
Must be minimum 7 inch (180mm) diameter (ID) high
temperature chimney listed to UL 103 HT (2100
ULC S629M.
Must use components required by the manufacturer
for installation.
Must maintain clearances required by the manufacturer
for installation.
Refer to manufacturers instructions for installation.
NOTE: In Canada when using a factory-built chimney it must
be safety listed, Type UL103 HT (2100
conforming to CAN/ULC-S629M, STANDARD FOR 650
FACTORY-BUILT CHIMNEYS.
Listed Chimney
Ceiling Support
Chimney
Connector
Floor
Protector
Figure 12.2 - Prefabricated Interior Chimney
o
F) or
o
F) CLASS "A" or
o
C
Listed Termination Cap
Storm Collar
Flashing