settinG tHe ReQuiReD teMPeRatuRe
The temperature setting can only be adjusted, when the heater is burning. Use
the adjustment keys N to adjust the temperature. First press either of the two
keys to switch on the function (the °C mark K will start blinking). Next, adjust the
temperature using the key on the right (Mmin.) to set the temperature to a higher
setting and the key on the left (Nhour) to lower the temperature. Press once to
increase the value one step. After approximately 10 seconds the °C mark will stop
blinking and the setting will be locked (Fig. G).
The available temperature settings range from 6°C minimum to 28°C maximum.
When the heater has been unplugged (or after a power failure), the temperature
will reset to the factory setting of 20°C.
G
sWitcHinG Off tHe HeateR
There are two ways to switch off the heater.
1
Press the
button L. The information display will show the CLOCK
signal. Within approximately one minute the flame will have extinguished.
2 Press the TIMER key , when you want to switch off the heater and ignite it
again with the timer the next time. This not only switches off the heater, but
it also activates the timer function.
H
tHe infORMatiOn DisPlay
The information display K not only serves as an indicator of the (set) time and
temperature (Sections C, D, and F), it also indicates any malfunctioning of the
heater. The code on the information display tells you what is the matter:
cODe
infORMatiOn
e - 0
Temperature within the heater too high.
f - 0
Power interrupted.
e - 1
Faulty thermostat.
f - 1
Faulty burner thermistor.
e - 2
Starting problems.
Re-ignite the heater immediately after
e - 23
extinguishing.
e - 5
Tipping-over protection.
e - 6
Poor burning.
e - 7
Room temperature
above 32°C.
e - 8
Defective booster.
e - 8 1
Abnormal frequency.
e - 9
Air filter dirty; or
Fuel pump dirty.
The heater has been in operation
continuously for a period of 65 hours
and has turned itself off automatically.
Out of fuel.
-- : --
+
Too little ventilation.
-- : --
+
Always contact your dealer for any malfunctioning not listed above and/or when
the error keeps occuring after taking the corrective measure as described above.
WHat tO DO
Cool-down and re-ignite.
Re-ignite the heater.
Contact your dealer.
Contact your dealer.
Contact your dealer.
Wait for approx. 30 sec.
and re-ignite after inserting
the plug again.
Re-ignite the heater.
Contact your dealer.
If necessary,
re-ignite the heater.
Contact your dealer.
Insert the plug into the wall-socket again.
Contact your dealer.
Clean filter.
Contact your dealer.
Switch the heater back on.
Refill removable tank.
Ventilate better.
In case of any
malfunctioning the
information display will
tell you what is the
matter.