Operation Of The Sanicubic® 1 Control Keypad (Ip67); Operation Of The Sanicubic® 2 Classic /Sanicubic® 2 Pro / Sanicubic® 2 Xl Remote Control Box; Sanicubic® Alarm Unit; Operation Of The Sanicubic® 1 / Sanicubic® 1 Wp Sanicubic® 2 Classic /Sanicubic® 2 Xl Wired Alarm Unit - SFA SANICUBIC 1 Notice De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
UK
Figure 2: Ventilation of the SANICUBIC® control box
6 .1 .1 . Operation of the SANICUBIC® 1 control keypad (IP67)
1/ General alarms:
Level alarm:
If the water level inside the device is abnormally high, the alarm LED lights
up red + engine starts up. Furthermore, if this LED flashes red, it indicates a
detection problem for the normal water level (Long dip tube).
Time alarm:
If the motor runs continuously for more than 1 minute, the red alarm LED
lights up.
2/ Alarm reset: The button on the keypad will only allow you to turn off the
red LED (it will turn green) if the problem that triggered the alarm has been
resolved. It also allows you to stop the ringing of the remote alarm control.
Mains alarm:
- If the LED is off, there is no power supply.
- When the device is powered on again, the LED flashes green, indicating that
the mains voltage has temporarily disappeared.
6 .1 .2 Operation of the SANICUBIC® 2 Classic /SANICUBIC® 2 Pro / SANI-
CUBIC® 2 XL remote control box
OPERATION OF THE ALARM
1/ General alarms:
Level alarm:
If the water level inside the device is abnormally high: the siren is triggered
+ the red alarm LED lights up + both motors start-up. If this LED flashes red,
it indicates a detection problem for the normal water level (Long dip tube).
Time alarm:
If one of the two motors runs for more than 1 minute: the siren is triggered +
the red alarm LED lights up + the other engine starts-up.
Mains alarm:
In case of power failure (or when unplugging the device): the siren is trigge-
red + the red alarm LED lights up + the yellow mains LED blinks.
2/ General alarm reset:
If the problem that triggered one of the alarms above disappears, the siren
stops, but the red alarm LED remains lit as a reminder of the fact that the sys-
tem encountered a problem. Either of the two keypad keys will stop the siren
in all cases, but it will only turn off the red LED if the problem that triggered
the alarm has been resolved. Alarms from the remote box will also remain ac-
tive until the problem has been solved. This prevents the system from being
«abandoned» by default.
6 .2 SANICUBIC® alarm unit
To wall mount the unit, use the following figure as a guide:
6 .2 .1 Operation of the SANICUBIC® 1 / SANICUBIC® 1 WP
SANICUBIC® 2 Classic /SANICUBIC® 2 XL wired alarm unit
The SANICUBIC® alarm unit does not require a separate power supply. The
power is supplied through the SANICUBIC®. In case of power failure, the
alarm unit's battery takes over.
Connection of the alarm unit to the device:
Connect the alarm cable directly to the unit.
1/ The red general alarm LED reproduces
the operation of the red LED on the base
card. The alarm unit sounds in the event
of an alarm as long as the fault is present.
To stop the alarm, press the reset (*)
button on the device's keypad or the
button under the alarm unit.
2/ The yellow «mains» LED indicates the
power status of the alarm unit
-Steady light = live SANICUBIC® connected
to the mains supply
-Flashing = power failure on the SANICUBIC®
1
Table 5: SANICUBIC® 1 / SANICUBIC® 1 WP / SANICUBIC® 2 Classic /
SANICUBIC® 2 XL alarm unit
1
Red general alarm LED
2
Yellow mains alarm LED (power supply indicator)
6 .2 .2 Operation of the SANICUBIC® 2 PRO HF alarm unit
w Unit powered by an electrical socket. Risk of death!
Table 6: SANICUBIC® 2 Pro alarm unit
1
Red general alarm LED
2
Yellow alarm transmission LED
3
Green mains alarm LED
The alarm unit is in HF -868 MHz connection with the SANICUBIC® 2 Pro. It
receives various alarm information from it. If other devices operating in HF
are disrupted by the system (or vice versa), a commutation of the HF -868
MHz coding, which connects the base card and the remote alarm unit, has
been anticipated. In case of interference with other nearby HF devices or
other SANICUBIC® 2 Pro devices, unplug the device and the remote module,
switch one or more of the four switches on the device's card (SW2) and do
likewise on the remote control unit.