General Information / Installation
DESCRIPTION
This submersible pump is designed for use as a utility
pump. Unit is equipped with a 3-prong grounding-type
power cord. Ball bearings on the motor shaft never need
lubrication. Automatic reset thermal protection.
SPECIFICATIONS
Power supply required ..................................115 V, 60 Hz
Motor duty.......................................................intermittent
Liquid Temp. Range ...............................0–25°C (32–77°F)
Individual Branch Circuit
Requirement (minimum) ............................................15 A
NOTICE: Not designed for applications involving salt
water or brine! Use with salt water or brine will void
warranty.
Pump water only with this pump.
NOTICE: Not for use in water where fish are present.
DISCHARGE FITTINGS CHART
Pump
Model No.
1 1/4" FBSP X 1" FNPT
62-3515-0
1" MNPT X 3/4" garden hose
ELECTRICAL SPECIFICATIONS
Motor
Motor
Full Load
H.P.
Amps
1/6
1.5
PUMP CAPACITY
Head in feet
0
Head in metres
0
Litres/minute
76
Gallons/minute
20
Included Adaptors
Minimum
Pumps
Circuit
Down
Req. (Amps)
To
15
7/16" (11 mm)
5
10
15
1.5
3.1
4.6
6.1
63
43
25
17
11
7
CUSTOMER HOTLINE: 1-877-455-5508
INSTALLATION
1. Install the pump on a hard level surface. Make sure
that the pump cannot pick up rocks, mud and debris,
etc. If neccesary, put a block under the pump to raise
it slightly. See Fig. 1.
Figure 1: Typical installations.
2. Protect the power cord from damage. Uncovered
cords should be routinely inspected for damage or
deterioration. DO NOT operate the pump if the cord
is damaged.
3. Choose an adaptor and install it as indicated in
Fig. 2.
Pump includes the adaptors below.
1/2, 3/4, or
1", barbed
hose adaptor
20
0
1 1/4 x 1" NPT
adaptor
0
1" NPT to
garden hose
adaptor
Figure 2: Adaptor connections.
Roofs
.3
Basements
.3
3696 0500 NEW
Includes
three
different
adaptors