cording to the heater requirements. Direct combustion
heaters should only be used in well vented areas in
order to avoid carbon monoxide poisoning;
• A rough estimate of opening required for each gallon
(US) of capacity is three square foot at heater level, for
direct-fired heaters;
• The heater is installed and connected to properly
grounded electrical outlet with adequate supply. (refer
to specifications for reference.
• Ensure that the machine resting surface or ground is
not made of flammable material.
• Minimum clearances from combustible material must
be: 30" from side and rear (air inlet) of heater 80"
from ceiling 40" on air outlet of heater.
• Never block air inlet (rear) or air outlet (front); In case
of very low temperatures add kerosene to the heating
oil;
• Connect the power cord to the outlet and wait 15 min
at least be fore starting heater, to allow pre-heated
filter warming heating oil inside the filter (NOT ON ALL
MODELS)
• Make sure heater is always under surveillance and keep
children and animals away from it;
• Before starting the heater always check free rotation of
ventilator;
• Heater is not ductable.
• Allow heater to fully complete its cooling cycle before
unplugging
• Unplug heater when not in use.
SAFETY DEVICES
The unit is fitted with an electronic flame control box. In
case of malfunction this box will cut in and stop the heater,
at the same time the reset lamp in the control box will light
up. Refer to "Reset Button" section for information.
Heaters are also equipped with an overheat thermostat
safety cut out which will stop the heater in case of over-
heating. This thermostat will reset automatically but you
will have to depress button on control panel before being
able to restart the heater.
OPERATION
Before any attempt of starting the heater is made, check
that your electrical supply conforms to the data on the
model plate.
The heater must be placed on a flat, stable and level sur-
face to avoid machine tipping and/or gas oil leakage from
the tank fuel cap. The flow of heat can be directed upward
with an approximate 10°angle: loosen the two locking
knobs (A) and tilt the combustion unit by pressing on the
handle until the desired angle is reached, then lock the
knobs by tightening.
WARNING:
Before start-up, always ensure the guard (B) has been com-
pletely pulled out, so as to guarantee maximum protection
of the machine resting surface.
Fuel Fired Portable Radiant Construction Heater
BURNER ANGLE ADJUSTMENT
A
FLOOR TEMPERATURE GUARD
B
4
Operating Instructions and Owner's Manual
PUSH UP OR
DOWN TO
ADJUST ANGLE