Programming; Configure The Kpr2000 - LiftMaster KPR2000 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PROGRAMMING

4
Confi gure the KPR2000.
Change the configure settings according to your application
(optional). Multiple configuration settings can be changed at one
time: enter program mode, change desired settings, then exit
program mode.
SET MASTER CODE
The 6 digit Master Code is used to prevent unauthorized access to the
system. To interface with the KPR2000, the manager will need a Master
Code (factory default code: 888888). We highly recommend immediate
update and recording of your Master Code.
Programming Step
Keystroke Combination
✱ (Master Code) #
1. Enter Program Mode
2. Update Master Code
0 (New Code) # (New Code) #
3. Exit Program Mode
SET ACCESS CONFIGURATION
There are 3 types of access configurations for the KPR2000:
• Card or PIN (Default): The User must present a valid Wiegand Card to
the KPR2000 or enter their PIN code followed by the # key, in order to
be granted access.
• Card Only: The User must present a valid Wiegand Card to the
KPR2000 in order to be granted access. The facility code and the ID
number are both read and validated as one block of Wiegand data.
• Card + PIN: The User must first present a valid Wiegand Card to the
KPR2000 and then enter their PIN code followed by the # key, in order
to be granted access.
Programming Step
Keystroke Combination
✱ (Master Code) #
1. Enter Program Mode
2. Card Only
3 0 #
OR
2. Card + PIN
3 1 #
OR
2. Card or PIN
3 2 #
3. Exit Program Mode
SET RELAY CONFIGURATION
The relay configuration sets the behavior of the output relay on activation.
Programming Step
Keystroke Combination
✱ (Master Code) #
1. Enter Program Mode
2. Pulse Mode
4 (1-99) # The relay time is 1-99 seconds
OR
2. Latch Mode
4 0 # Sets the relay to ON/OFF latch mode
3. Exit Program Mode
SET WIEGAND INPUT/OUTPUT OPTIONS
The KPR2000 offers input and output for industry standard Wiegand
devices (refer to Specifications). Default is HID 26 bit.
Programming Step
Keystroke Combination
✱ (Master Code) #
1. Enter Program Mode
2. Set Wiegand Format
9 (Bit Format) # Bit Format = Valid 2 digit
format (example: 26 or 30)
3. Exit Program Mode
(default is 5 seconds)
SET DOOR OPEN TOO LONG (DOTL) OR FORCED ALARM
This setting enables both DOTL and Door Forced Alarms and requires an
external sensor input. The Door Forced alarm output timing can be set
from 1-3 minutes (default is 1 minute). The Door Open Too Long (DOTL)
timing is fixed to 1 minute and only sounds the built in buzzer. Factory
default is OFF.
Programming Step
1. Enter Program Mode
2. DOTL /Door Forced Alarm
OFF
OR
2. DOTL /Door Forced Alarm
ON
2. Door Forced Output Timing 9 (1-3) #
3. Exit Program Mode
SET STRIKE-OUT ALARM
The strike-out alarm will engage after 10 failed card/PIN attempts in a ten
minute period. Factory default is OFF. The strike-out alarm can be set to
deny access for 10 minutes or it can be set to operate the alarm for 10
minutes. NOTE: Enter Master Code or Valid Card to silence all alarm
outputs.
Programming Step
Keystroke Combination
1. Enter Program Mode ✱ (Master Code) #
2. Strike-Out Alarm OFF
7 0 # (Factory default)
OR
2. Strike-Out ON
7 1 # Access will be denied for 10 minutes
OR
2. Strike-Out Alarm ON
7 2 #
3. Exit Program Mode
SET AUDIBLE AND VISUAL RESPONSE
Factory default is ON.
Programming Step
Keystroke Combination
1. Enter Program Mode ✱ (Master Code) #
2. Control Backlight
ON = 7 5 #
OR
2. Control LED
ON = 7 7 #
OR
2. Control Sounds
ON = 7 9 #
3. Exit Program Mode
SET WIEGAND KEYPAD MODE
Programming Step
Keystroke Combination
1. Enter Program Mode ✱ (Master Code) #
2. Set Keypad Mode
6 2 # ASCII Keypad Mode
OR
2. Set Keypad Mode
6 3 # 26 bit Card Keypad Mode (factory default)
3. Exit Program Mode
SET 26 BIT FORMAT FACILITY CODE
Programming Step
Keystroke Combination
1. Enter Program Mode ✱ (Master Code) #
2. Set Facility Code
8 0 # Ignores facility code (Factory default)
8 (Facility Code) # (1 - 255)
3. Exit Program Mode
5
Keystroke Combination
✱ (Master Code) #
6 0 #
6 1 # (DOTL: Alarm sounds for 1 minute.
Door Forced: Alarm sounds for 1-3
minutes and enables alarm output.)
OFF = 7 4 #
OFF = 7 6 #
OFF = 7 8 #

Publicité

Table des Matières
loading

Table des Matières